Eprobe-mediated screening system for somatic mutations in the KRAS locus
- Authors:
- Published online on: March 30, 2015 https://doi.org/10.3892/or.2015.3883
- Pages: 2719-2727
-
Copyright: © Atsumi et al. This is an open access article distributed under the terms of Creative Commons Attribution License [CC BY_NC 3.0].
Abstract
Introduction
The Kirsten rat sarcoma viral oncogene homolog (KRAS) protein is an important signaling mediator in the epidermal growth factor receptor (EGFR) pathway, which regulates cell growth and is commonly targeted in cancer therapy (1,2). Mutations in codon 12 and 13 of the KRAS gene are found in ~30% of colorectal cancer (CRC) cases and are associated with an increased risk of recurrence and mortality (3). Various preclinical and clinical studies have revealed that the presence of KRAS activating mutations in CRC correlates with resistance to EGFR monoclonal antibodies (EGFR mAb), such as cetuximab (Erbitax) and panitumumab (Vectibix) (4–8). As such, the US Food and Drug Administration (FDA) has recommended that EGFR mAbs should not be given to patients with tumors harboring KRAS mutations in codon 12 or 13 (6). This requires the KRAS mutation status to be assessed prior to treatment, yet clinicians currently lack the ability to detect these mutations with a high sensitivity, high-throughput and simple method.
Sanger sequencing is the gold standard for detecting KRAS mutations; however, it is highly inefficient and has relatively low sensitivity. In response to increasing demands in the medical setting, various KRAS mutation detection assays have been developed and described in the literature and different providers offer commercial test kits (9,10). Real-time PCR based methods are the most cost-effective and require shorter working times than other methods. The Scorpion, Amplification Refractory Mutation System (ARMS), and TaqMelt systems are among the widely used real-time PCR-based KRAS mutation detection systems (11–13). While these are highly sensitive and reproducible methods, each has its advantages and disadvantages. The Scorpion and ARMS methods are based on mutation-matched primers, which amplify mutated loci more efficiently than primers with wild-type (WT) sequences or other mutations. Seven reactions are necessary to detect the mutation status and thus the amount of DNA needed is ~800 ng (12). Alternatively, the TaqMelt method is based on the melting curve analysis after PCR and is able to detect a total of 19 mutations in KRAS codons 12, 13 and 61, yet it requires sophisticated instruments and software. Hence, a more simple and cost-effective detection assay capable of producing high quality results may greatly benefit cancer diagnostics.
In addition to mutation sequencing at clinical laboratories, most of these assays use an amplification-dependent detection method sometimes combined with melting curve analysis of the amplicon. The use of high-throughput sequencing for detecting KRAS mutations has been described and some providers have started to offer dedicated cancer sequencing panels (14). While high-throughput sequencing has been used as a reference for testing the performance of new KRAS detection assays, this approach could be extended to wider applications. Assuming that PCR-based detection assays are able to achieve a mutation sensitivity greater than or equal to that of a Sanger sequencing-based approach, PCR-based detection assays should be sufficient to confirm mutations found by high-throughput sequencing.
In the present study, we aimed at developing a new PCR-based detection assay using Eprobe, or ‘Eprobe-mediated PCR’. Eprobe is a fluorescence probe enabling quantification analysis and melting curve analysis using real-time PCR machines (15–17). Eprobe binds complementary DNA with higher affinity than normal oligonucleotides by using cationic dye moieties (18) and thus leads to a competitive effect observed in primer annealing and extension. This characteristic enables specific sequence enrichment-similar to using peptide and locked nucleic acids (PNA and LNA, respectively) as a clamping probe (19–27), to allow for the detection of even miniscule amounts of mutated DNA. Notably, this method can detect somatic mutations with high accuracy in simple steps that employ commonly used laboratory equipment and a small amount of DNA, unlike other methods. Thus, Eprobe-mediated PCR enables efficient detection of mutation status and is a major advance in cancer diagnostics. Here, we demonstrate a novel method to detect KRAS mutations at codon 12 and 13 by Eprobe-mediated PCR with a higher sensitivity than conventional Sanger sequencing, which is more time and cost-effective than other technologies.
Materials and methods
Reagents and control DNA
DNA oligonucleotides were purchased from Sigma-Aldrich (Ishikari, Japan), and stored as 100 mM stock solutions in 10 mM Tris-HCl with 1 mM EDTA (pH 8.0). WT human genomic DNA was purchased from Promega (Tokyo, Japan). Heterozygote human genomic DNA with seven mutations (G12A, G12C, G12D, G12R, G12S, G12V and G13D) in the KRAS gene codon 12 and 13 were obtained from Horizon Diagnostics (Cambridge, UK). Eprobes (shown in Table I) were obtained from K.K. DNAFORM (Yokohama, Japan). Point mutations in codon 12 of the KRAS gene (GAT, GCT, GTT, AGT, TGT) were cloned into the plasmid pGEM-T (Promega) as previously described (26) and stored in glycerol at −80°C for long-term conservation. Point mutation of codon 13 (GAC) in the KRAS gene was prepared using the same protocol. The KRAS codon 12 (CGT) point mutation was prepared using the synthetic DNA ordered and inserted into a pUC57 plasmid (GenScript, Tokyo, Japan). The sequences of WT and all seven mutant clones were verified on ABI PRISM 3100 Avant (Applied Biosystems, Tokyo, Japan), diluted in TE buffer and stored at −20°C until use.
Design of Eprobe and real-time PCR
Human KRAS specific primers for KRAS codon 12 and 13 (KRAS-F, 5′-TTATAAGG CCTGCTGAAAATGACTGAA-3′ and KRAS-R, 5′-TGAATTAGCTGTATCGTCAAGGCACT-3′) were based on literature (28) and amplified a 92 bp DNA fragment. Different PCR reagents and enzyme master mixes were used with specific Eprobes during PCR. Eprobes were designed complementary to the reverse strand for mutation detection by the WT probe and to the forward strand for genotyping by the mutant (MT) Eprobe (Table I).
Highly sensitive mutation detection by high resolution melting analysis
PCR assays were performed using 1.5 μl of 5X LightCycler 480 Genotyping Master, 0.5 μl of DMSO, 2.5 μl of diluted template DNA (2.5 ng/reaction), 0.5 μM of forward primer, 0.1 μM of reverse primer and 0.4 μM Eprobe in a total volume of 10 μl. Amplification reactions and melting curve analysis were from real-time PCR experiments run on a Rotor-Gene Q (Qiagen K.K., Tokyo, Japan) after activation of the hot-start enzyme for 10 min at 95°C, followed by 50 cycles of 15 sec at 95°C, 15 sec at 63°C and 12 sec at 72°C. Amplification signals were detected during the annealing step of each cycle at 63°C, using a SYBR Green I (483 nm) filter. Melting curve analysis and high resolution melting analysis were performed from 40 to 75°C with a temperature increase of 0.5°C/sec. All PCR reactions and melting curve experiments were performed in triplicate.
PCR standard curves were generated by analyzing Ct values acquired from the Rotor-Gene Q instrument with Rotor-Gene Q-Pure Detection (version 2.0.2; Qiagen K.K.). The data was transferred to Microsoft Excel (Microsoft, Redmond, VA, USA) and Ct values were plotted against the template DNA concentrations. Logarithmic trend lines were added, and equations and R-squared values obtained by using Microsoft Excel are shown in the graphs. Microsoft Excel provides slopes as log10(x) values, which were transformed into ln(x) by multiplying the slope value by 2.303 [ln(x) = 2.303 × log10(x)]. The PCR efficiency to evaluate the competing effect is based on seven different concentrations of WT plasmid DNA templates. The slope values were used to calculate PCR efficiencies with a Thermo Fisher online web tool at: http://www.thermoscientificbio.com/webtools/qpcref-ficiency/. Amplification, melting and derivative melting curves were obtained with the Rotor-Gene Q instruments as indicated above, and the data points were transferred to Microsoft Excel for plotting.
Mutation genotyping by melting curve analysis
Amplification reactions using AmpliTaq Gold were set up in 96-well plates using 5 μl template DNA (50 ng/reaction), 12.5 μl of AmpliTaq Gold PCR Master Mix, 0.1 μM of forward primer, 0.5 μM of reverse primer, and 0.2 μM Eprobe in a total volume of 25 μl. Real-time PCR experiments were run on a Rotor-Gene Q or LightCycler 480 (Roche Diagnostics, Mannheim, Germany) after activation of the hot-start enzyme for 10 min at 95°C, followed by 50 cycles of 15 sec at 95°C, 15 sec at 60°C, and 12 sec at 72°C. Amplification signals were detected during the annealing step of each cycle at 60°C, using a SYBR-Green I (Rotor-Gene Q, 483 nm; LightCycler 480, 483–533 nm) filter. For melting curve analysis, the PCR was followed by heating the reaction mixture to 95°C for 15 sec, cooling to 37°C, holding at 37°C for 7 min, and then slowly heating again to 95°C at a ramp rate of 2.2°C/sec with continuous fluorescence acquisition at the indicated wavelengths. Samples were analyzed in triplicate. Genotyping was performed by the ‘Melting Curve Genotyping’ mode of LightCycler 480 software (version 1.5.1.62; Roche Diagnostics). After setting of the parameters (temperature range, 55–70°C; score threshold, 0.70; and resolution threshold, 0.20), ‘auto grouping’ was carried out for the mutation genotyping by comparison with standard samples for each mutation ratio.
Amplification, melting and derivative melting curves were obtained from the LightCycler 480 instrument as indicated above, and the data points were transferred to Microsoft Excel for plotting.
Clinical samples
Tumor samples were obtained from patients with CRC who were surgically treated at Gunma University Hospital (Gunma, Japan) between 2002 and 2006. All the samples were immediately frozen after surgical resection and stored at −80°C until DNA extraction. Tumor samples were also preserved in a formalin-fixed paraffin-embedded (FFPE) form. Previous examination with a microscope confirmed that each FFPE tissue sample contained a sufficient number of tumor cells for analysis. In the present study, 92 frozen and 35 FFPE tissue samples were available for gene analysis. An institutional approval and an informed consent from all the patients were obtained in writing.
DNA extraction
DNA was extracted from a 3- to 5-mm cube of frozen tissues that were collected using a DNA Mini kit (Qiagen K.K.) according to the manufacturer’s instructions. For FFPE samples, two to three 5-μm thick sections were sliced from each block with the maximum number of tumor-rich areas. To suppress normal tissue contamination, the tumor area of the section was macro dissected. DNA was extracted using a QIAamp DNA FFPE tissue kit (Qiagen K.K.) according to the manufacturer’s instructions. After extraction, all the DNA templates were diluted in TE buffer to 10 ng/μl and stored at −20°C. Stored templates were diluted to 1 ng/μl with H2O just before Eprobe-PCR with the WT Eprobe assay.
Sanger sequencing
Mutation screening in clinical samples for KRAS codon 12 and 13 was performed using PCR conditions and direct sequencing following previously described protocols (25). The PCR reactions were performed in a final volume of 25 μl containing GeneAmp 10X PCR Gold buffer (Life Technologies, Carlsbad, CA, USA), 1.5 mM of MgCl2 solution, 200 μM of dNTPs, 500 nM of each primer (forward primer, 5′-TGAAGTACAGTTCATTACGATACACG-3′ and reverse primer, 5′-GGAAAGTAAAGTTCCCATATTAATGGT-3′), 1 unit of AmpliTaq Gold DNA polymerase (Life Technologies), and 20 ng of genomic DNA. Thermal cycling conditions included preincubation at 94°C for 5 min, followed by 35 cycles at 94°C for 15 sec, 60°C for 30 sec, 72°C for 1 min and extension at 72°C for 5 min. The PCR products were purified using the QIAquick PCR purification kit (Qiagen K.K.) and processed for DNA sequencing reaction using ABI PRISM BigDye Terminator version 3.1 (Applied Biosystems) with a forward primer. Sequence data were generated using the ABI PRISM 3100 DNA Analyzer (Applied Biosystems).
Next-generation sequencing
Target sequencing libraries for Illumina HiSeq sequencing were prepared using an Illumina TruSeq DNA Library Prep kit (Illumina, San Diego, CA, USA) with multiplexed sample barcoding and amplicon tagging following the manufacturer’s instructions. The Illumina sequencing libraries were run on the Illumina HiSeq 2000 utilizing a 100 bp single end sequencing read protocol.
FASTQ files generated from either the Illumina HiSeq sequencing runs were trimmed with the adapter sequence from sample data with FASTX-toolkit (v0.0.13.2). The trimmed data were mapped to references with the Burrows-Wheeler aligner (v0.6.2-r126). SAM tools (v0.1.18) were utilized to convert the aligned sequence data from a sequence alignment/map (SAM) to a binary sequence alignment (BAM) format. The pileup files from BAM files were created with SAM tools. Single nucleotide polymorphism (SNP) was examined using VarScan2 (v2.3.5jar). SNPs were characterized as being significantly different from the reference sequence if the variant to reference base frequency was >1%.
Results
Working principle of mutation enrichment by competitive, allele-specific Eprobe-mediated real-time PCR
Eprobe-mediated PCR is able to detect the targeted mutation via enrichment of the mutant amplicon by a simple design (Fig. 1). During the reaction, the WT Eprobe binds the WT template with high affinity in the annealing and extension steps, thus preventing generation of the PCR amplicon. In contrast, a mismatch base pair between the WT Eprobe and the mutant template reduces hybridization, resulting in enrichment of the mutant amplicon. The WT Eprobe is designed complementary to the reverse strand for mutation detection (Table I). Standard PCR protocols are used with the exception of an asymmetric primer ratio (KRAS-F:KRAS-R=5:1) to improve Eprobe binding to the forward strand. The annealing temperature was set to 63°C, which is slightly lower than the Tm value of the full-complementary match between the WT Eprobe and WT template. Taq DNA polymerase lacking 5′-3′ exonuclease activity in LightCycler 480 Genotyping Master is utilized to avoid degradation of WT Eprobe, which binds the WT template during the extension reaction.
Confirmation of Eprobe-mediated competitive real-time PCR
We tested a serial dilution range from 102 to 108 copies of KRAS WT and MT plasmid DNA (Fig. 2). Each dilution was assayed in triplicate. The WT of Eprobe detected amplification of the WT template in real-time and demonstrated a good linear range for detection in the dilution series. Standard curves of triplicate Ct values for each dilution resulted in an 83% amplification efficiency, as calculated from the slope (Fig. 2 and Table II). In contrast, G12C and G13D plasmid DNA templates failed to show amplification curves; however, a mismatch peak was detected on the melting curve analysis (data not shown). These results suggest that the amplifications were successful, but the lower affinity hybridization of the WT Eprobe to the mutant DNA limits the amplification signal. Other MT plasmid templates exhibit good amplification curves and a linear detection range in the dilution series with efficiency values of 93–100% (Table II); thus demonstrating that the competitive effect is inefficient for the MT template, yet present between the WT Eprobe and KRAS-R.
Melting curve analysis and high resolution melting (HRM) analysis by competition with WT Eprobe
We evaluated the ability of KRAS low-level mutation detection using 25,000 copies/reaction of plasmid DNA and 2.5 ng/reaction of human genomic DNA. Samples of each mutation ratio were prepared by diluting mutant plasmid DNA with WT plasmid DNA, and then analyzing mutant detection by real-time PCR. Melting curve analysis and high resolution melting (HRM) analysis provided Tm values for the indicated genotypes. The Tm of KRAS WT (64.2°C) was higher than the Tm values of all seven KRAS mutant types (MTs) in codon 12 and 13 (57.3–54.5°C). For each mutant, a >1% mutation ratio exhibited peaks in the lower region of the Tm values; however, it was difficult to determine values <1% since the curve shapes failed to show distinct peaks.
On HRM analysis, we detected small changes of curves at <1% mutation ratio by comparing them to the standard curve derived from the WT amplicon (Fig. 3). We evaluated the numerical value from the confidence scores of each sample assigned by the comparison of the melting curves with the WT template. The threshold of KRAS mutation detection was set at 98%. Using plasmid DNA, we achieved mutation detection as low as a 0.05–0.1% ratio for each genotype (Table III), yet the human genomic DNA showed an amplification efficiency lower than that of the plasmid DNA. Notably, Eprobe-PCR achieved 1–2.5% mutation detection for each genotype using 2.5 ng of genomic DNA (Table III). These results indicate that Eprobe-PCR with WT Eprobe can detect KRAS mutations with high sensitivity even when present at low levels.
Melting curve analysis by Eprobe for mutation genotyping
We tested mutation genotyping by MT Eprobes as presented in Table I. The lengths of Eprobes were shorter than that of the WT Eprobe for the low-level mutation detection to avoid competition between the primers and Eprobes. PCR reactions using AmpliTaq Gold Master Mix were run on LightCycler 480 to generate a melting genotyping for each MT template (Fig. 4). Some combinations, such as G12R mutation and G12A MT Eprobe, exhibited a slightly higher Tm value than other mutations and the WT template on melting curve analysis. To confirm this, we used a positive control for each mutation genotype and the highest Tm value to identify the genotype. Importantly, Eprobe-based PCR yielded a genotyping sensitivity as low as a 5 to 10% mutation ratio for each mutant.
Assay of clinical samples
Eprobe-based PCR with WT Eprobe only requires a small amount of DNA sample to KRAS mutations; this may then be followed with MT Eprobe PCR to both verify these results as well as genotype the mutation (Fig. 5). To demonstrate the feasibility of Eprobe-based PCR in a clinical setting, we performed the assay on DNA extracted from 92 frozen and 35 FFPE CRC tissue samples. To determine the mutation status with the WT Eprobe, 2.5 ng of genomic DNA from each clinical sample was used per reaction. In the DNA extracted from the frozen tissue, Eprobe mediated PCR by WT Eprobe detected 33/92 mutated samples (36%), whereas Sanger sequencing identified mutation in 20 samples (22%) that were all detected by the Eprobe method (Table IV). These results demonstrate that the Eprobe-PCR method is sufficient to detect KRAS mutations using a small amount of clinical sample. Genotyping results with the MT Eprobe identified 20 mutant DNA samples also detected by Sanger sequencing, and 13 that went undetected (Table IV).
We performed a next-generation sequencing (NGS) on these 13 genomic DNA samples that gave differing results with the Eprobe-PCR and Sanger sequencing methods and one that yielded an unclear result with Sanger sequencing (Table V). NGS analyses showed that the 13 DNA samples contained KRAS mutations with a 1–10% mutation ratio and were consistent with the Eprobe-PCR results. Furthermore, of the 35 DNA samples extracted from the FFPE tissue, 10 (29%) were positive for KRAS mutations that were consistent with the results from the Sanger sequencing (Table VI). These findings demonstrate that Eprobe-PCR with the WT Eprobe allows for the detection of KRAS mutations with high sensitivity, consistent to that observed with NGS and more efficient than Sanger sequencing.
Discussion
In the present study, we have presented a method to detect and genotype somatic KRAS mutations in CRC samples using Eprobe-mediated PCR. Eprobes can be used directly for amplification analysis and melting curve analysis for mutation detection and genotyping, respectively. It can also be used as a competitive probe to enrich for mutant amplicon.
The guidelines detailing the design of Eprobes to enrich for mutations via competition-mediated PCR are simple and have been previously published (17). Our group designed and optimized the Eprobes for the present study using the tool ‘ECHO/DNA Thermodynamics’ (18). The WT Eprobe overlaps with the reverse primer at two bases, causing competition during the annealing and extension steps. An annealing temperature slightly lower than the Tm value of the WT Eprobe/template combination (63 vs. 64.2°C) yields a good competition effect. In addition, it is essential to use Taq DNA polymerase that lacks 5′-3′ exonuclease activity, since this activity is able to digest the WT Eprobe during the extension reaction. These optimization techniques effectively prevent amplification of the WT template and lead to enrichment of the mutant amplicons. The Eprobe method exhibits a lower competition effect than PNA and LNA (19–27); however, it also works as a detection probe. The relatively low efficiency value of the WT amplification (83% compared to 93–100%, Table II) allows the WT Eprobe to be used as both a detection probe and a competition probe. This competitive effect enables the detection of mutations present at low ratios (0.05–0.1% mutant in WT background). The results demonstrated the detection of the target sequence by fluorescence and primer competition to reduce WT template amplification with one WT Eprobe. Furthermore, this system simplifies the process to detect KRAS mutations in codons 12 and 13, and reduces costs since it only requires a standard primer set, PCR reaction mix and an Eprobe.
To assess Eprobe-mediated PCR performance in a clinical setting, we assayed 92 samples extracted from frozen CRC tissues and evaluated the accuracy of the assay in comparison with the Sanger sequencing. Significantly, out of 92 samples, our WT Eprobe detected the presence of mutations in 33 samples (36%), including 20 (27%) identified as mutants by the Sanger sequencing, and 13 samples (14%) not detected by Sanger but confirmed by NGS. We evaluated this discrepancy in KRAS mutation genotyping by Eprobe-mediated PCR with MT Eprobes and NGS (Table V). Eprobes are designed to not overlap with primers and have Tm values below the annealing temperatures of the PCR primers. The MT Eprobes accurately genotyped each of the 33 samples identified as mutants by the WT Eprobe. This demonstrates that Eprobe-mediated PCR is able to detect even a small amount of mutated KRAS DNA, which the conventional sequencing method cannot. Sanger sequencing is the gold standard for identification of KRAS mutations in codons 12 and 13, yet it has a detection threshold of at least 20% (29). Thus, in a clinical setting, Eprobe-mediated PCR may provide more accurate information for determining which anti-EGFR mAb to use for the CRC patients. NGS may become the primary method to detect somatic mutations in order to ensure the necessary sensitivity and accuracy required by clinical standards. Our Eprobe-mediated PCR method is independent of the NGS method, and offers a more time and cost-effective method with equivalent sensitivity and accuracy; and thus may be a suitable alternative to NGS or a second method to confirm data acquired by NGS.
We also assayed clinical samples from FFPE tissue and found no discrepancy between the results from Eprobe-mediated PCR and Sanger sequencing (Table VI). In general, most clinical samples are fixed and preserved for pathological assessment in hospitals or institutes. However, the DNA extracted from the FFPE tissues is fragmented and chemically modified, making it difficult to use this DNA in molecular studies. The target base length is important for successful PCR when assaying DNA isolated from FFPE samples (32). As the Eprobe and primers in the present study are designed to generate a 92 bp amplicon, the PCR reaction is more likely to be successful even with short fragmented DNA obtained from FFPE tissues. Nevertheless, further investigation with larger sample sizes is required to verify the usefulness of Eprobe-mediated PCR in DNA isolated from FFPE samples.
Conventional real-time PCR-based KRAS mutation detection kits have a detection sensitivity of 95–99% and a specificity of 100% (30). Our Eprobe-PCR method satisfies these requirements as it detects mutated DNA (via the WT Eprobe) present at 0.05–0.1% in plasmid DNA and 1–2.5% in human genomic DNA as determined by HRM analysis. This raises the specificity to 100% for detecting mutations using these templates.
The FDA recommends that CRC patient tumor biopsies be assessed for KRAS mutation status prior to treatment with anti-EGFR mAbs. Our method has the potential to quickly provide necessary and sufficient information to physicians. It is also likely to reduce the cost of gene sequencing not only for KRAS, but also other common oncogenic mutations, including those BRAF, PIK3CA and PTEN (31).
Eprobe-mediated PCR is superior to other methods, such as Scorpion, ARMS and TaqMelt, in terms of the amount of DNA required. Notably, only 2.5 ng of template DNA samples is needed for detection by Eprobe-PCR, compared to ~100 ng/μl for other methods (11–13). The need for only a small amount of template is beneficial since DNA extraction is laborious and time-consuming. Furthermore, excess template can be used for future analyses with other methods; this is particularly useful in cases where only a small amount of tissue is obtained.
In conclusion, we have developed a novel detection system capable of detecting KRAS mutations with high sensitivity using Eprobe-mediated PCR and compared its performance to Sanger sequencing and NGS. The simplicity and high sensitivity of Eprobe PCR may be suitable in a clinical setting that requires swift and accurate KRAS gene mutation detection.
Acknowledgments
We acknowledge Dr Matthias Harbers for his contributions to the manuscript preparation. This study was supported by i) research grants for RIKEN Omics Science Center from the Japanese Ministry of Education, Culture, Sports, Science and Technology (MEXT) to Y.H., ii) a research grant from the Japanese Ministry of Education, Culture, Sports, Science and Technology (MEXT) through RIKEN Preventive Medicine and Diagnosis Innovation Program to Y.H., iii) a Research Grant from the Japanese Ministry of Education, Culture, Sports, Science and Technology (MEXT) to the RIKEN Center for Life Science Technologies, iv) FY2013 subsidy of expenses by METI (Minister of Economy, Trade and Industry) for measures for small business support, and v) a research grant and operational grant for the Division of Thoracic and Visceral Organ Surgery, Gunma University Graduate School of Medicine from the Ministry of Education, Culture, Sports, Science and Technology (MEXT) of the Japanese Government to K.S.
References
Mendelsohn J and Baselga J: Epidermal growth factor receptor targeting in cancer. Semin Oncol. 33:369–385. 2006. View Article : Google Scholar : PubMed/NCBI | |
Downward J: Targeting RAS signalling pathways in cancer therapy. Nat Rev Cancer. 3:11–22. 2003. View Article : Google Scholar : PubMed/NCBI | |
Andreyev HJ, Norman AR, Cunningham D, Oates JR and Clarke PA: Kirsten ras mutations in patients with colorectal cancer: The multicenter ‘RASCAL’ study. J Natl Cancer Inst. 90:675–684. 1998. View Article : Google Scholar : PubMed/NCBI | |
Allegra CJ, Jessup JM, Somerfield MR, Hamilton SR, Hammond EH, Hayes DF, McAllister PK, Morton RF and Schilsky RL: American Society of Clinical Oncology provisional clinical opinion: Testing for KRASgene mutations in patients with metastatic colorectal carcinoma to predict response to anti-epidermal growth factor receptor monoclonal antibody therapy. J Clin Oncol. 27:2091–2096. 2009. View Article : Google Scholar : PubMed/NCBI | |
Lièvre A, Bachet JB, Le Corre D, Boige V, Landi B, Emile JF, Côté JF, Tomasic G, Penna C, Ducreux M, et al: KRASmutation status is predictive of response to cetuximab therapy in colorectal cancer. Cancer Res. 66:3992–3995. 2006. View Article : Google Scholar | |
Normanno N, Tejpar S, Morgillo F, De Luca A, Van Cutsem E and Ciardiello F: Implications for KRAS status and EGFR-targeted therapies in metastatic CRC. Nat Rev Clin Oncol. 6:519–527. 2009. View Article : Google Scholar : PubMed/NCBI | |
Bardelli A and Siena S: Molecular mechanisms of resistance to cetuximab and panitumumab in colorectal cancer. J Clin Oncol. 28:1254–1261. 2010. View Article : Google Scholar : PubMed/NCBI | |
Amado RG, Wolf M, Peeters M, Van Cutsem E, Siena S, Freeman DJ, Juan T, Sikorski R, Suggs S, Radinsky R, et al: Wild-type KRAS is required for panitumumab efficacy in patients with metastatic colorectal cancer. J Clin Oncol. 26:1626–1634. 2008. View Article : Google Scholar : PubMed/NCBI | |
Cavallini A, Valentini AM, Lippolis C, Campanella D, Guerra V and Caruso ML: KRASgenotyping as biomarker in colorectal cancer: A comparison of three commercial kits on histologic material. Anticancer Res. 30:5251–5256. 2010.PubMed/NCBI | |
Malapelle U, Carlomagno C, de Luca C, Bellevicine C and Troncone G: KRAS testing in metastatic colorectal carcinoma: Challenges, controversies, breakthroughs and beyond. J Clin Pathol. 67:1–9. 2014. View Article : Google Scholar | |
Lee S, Brophy VH, Cao J, Velez M, Hoeppner C, Soviero S and Lawrence HJ: Analytical performance of a PCR assay for the detection of KRAS mutations (codons 12/13 and 61) in formalin-fixed paraffin-embedded tissue samples of colorectal carcinoma. Virchows Arch. 460:141–149. 2012. View Article : Google Scholar : | |
Gonzalez de Castro D, Angulo B, Gomez B, Mair D, Martinez R, Suarez-Gauthier A, Shieh F, Velez M, Brophy VH, Lawrence HJ, et al: A comparison of three methods for detecting KRAS mutations in formalin-fixed colorectal cancer specimens. Br J Cancer. 107:345–351. 2012. View Article : Google Scholar : PubMed/NCBI | |
Tol J, Dijkstra JR, Vink-Börger ME, Nagtegaal ID, Punt CJ, Van Krieken JH and Ligtenberg MJ: High sensitivity of both sequencing and real-time PCR analysis of KRASmutations in colorectal cancer tissue. J Cell Mol Med. 14:2122–2131. 2010. View Article : Google Scholar | |
Chambers PA, Stead LF, Morgan JE, Carr IM, Sutton KM, Watson CM, Crowe V, Dickinson H, Roberts P, Mulatero C, et al: Mutation detection by clonal sequencing of PCR amplicons and grouped read typing is applicable to clinical diagnostics. Hum Mutat. 34:248–254. 2013. View Article : Google Scholar | |
Ikeda S, Kubota T, Yuki M and Okamoto A: Exciton-controlled hybridization-sensitive fluorescent probes: Multicolor detection of nucleic acids. Angew Chem Int Ed Engl. 48:6480–6484. 2009. View Article : Google Scholar : PubMed/NCBI | |
Lezhava A, Ishidao T, Ishizu Y, Naito K, Hanami T, Katayama A, Kogo Y, Soma T, Ikeda S, Murakami K, et al: Exciton Primer-mediated SNP detection in SmartAmp2 reactions. Hum Mutat. 31:208–217. 2010. View Article : Google Scholar : PubMed/NCBI | |
Hanami T, Delobel D, Kanamori H, Tanaka Y, Kimura Y, Nakasone A, Soma T, Hayashizaki Y, Usui K and Harbers M: Eprobe mediated real-time PCR monitoring and melting curve analysis. PLoS One. 8:e709422013. View Article : Google Scholar : PubMed/NCBI | |
Kimura Y, Hanami T, Tanaka Y, de Hoon MJ, Soma T, Harbers M, Lezhava A, Hayashizaki Y and Usui K: Effect of thiazole orange doubly labeled thymidine on DNA duplex formation. Biochemistry. 51:6056–6067. 2012. View Article : Google Scholar : PubMed/NCBI | |
Nagai Y, Miyazawa H, Huqun, Tanaka T, Udagawa K, Kato M, Fukuyama S, Yokote A, Kobayashi K, Kanazawa M, et al: Genetic heterogeneity of the epidermal growth factor receptor in non-small cell lung cancer cell lines revealed by a rapid and sensitive detection system, the peptide nucleic acid-locked nucleic acid PCR clamp. Cancer Res. 65:7276–7282. 2005. View Article : Google Scholar : PubMed/NCBI | |
Arcila M, Lau C, Nafa K and Ladanyi M: Detection of KRAS and BRAFmutations in colorectal carcinoma roles for high-sensitivity locked nucleic acid-PCR sequencing and broad-spectrum mass spectrometry genotyping. J Mol Diagn. 13:64–73. 2011. View Article : Google Scholar : PubMed/NCBI | |
Dono M, Massucco C, Chiara S, Sonaglio C, Mora M, Truini A, Cerruti G, Zoppoli G, Ballestrero A, Truini M, et al: Low percentage of KRASmutations revealed by locked nucleic acid polymerase chain reaction: Implications for treatment of metastatic colorectal cancer. Mol Med. 18:1519–1526. 2012. View Article : Google Scholar | |
Oh JE, Lim HS, An CH, Jeong EG, Han JY, Lee SH and Yoo NJ: Detection of low-level KRASmutations using PNA-mediated asymmetric PCR clamping and melting curve analysis with unlabeled probes. J Mol Diagn. 12:418–424. 2010. View Article : Google Scholar : PubMed/NCBI | |
Beau-Faller M, Legrain M, Voegeli A-C, Guérin E, Lavaux T, Ruppert AM, Neuville A, Massard G, Wihlm JM, Quoix E, et al: Detection of K-Rasmutations in tumour samples of patients with non-small cell lung cancer using PNA-mediated PCR clamping. Br J Cancer. 100:985–992. 2009. View Article : Google Scholar : PubMed/NCBI | |
Däbritz J, Hänfler J, Preston R, Stieler J and Oettle H: Detection of Ki-ras mutations in tissue and plasma samples of patients with pancreatic cancer using PNA-mediated PCR clamping and hybridisation probes. Br J Cancer. 92:405–412. 2005.PubMed/NCBI | |
Araki T, Shimizu K, Nakamura K, Nakamura T, Mitani Y, Obayashi K, Fujita Y, Kakegawa S, Miyamae Y, Kaira K, et al: Usefulness of peptide nucleic acid (PNA)-clamp smart amplification process version 2 (SmartAmp2) for clinical diagnosis of KRAS codon 12 mutations in lung adenocarcinoma: Comparison of PNA-clamp SmartAmp2 and PCR-related methods. J Mol Diagn. 12:118–124. 2010. View Article : Google Scholar | |
Tatsumi K, Mitani Y, Watanabe J, Takakura H, Hoshi K, Kawai Y, Kikuchi T, Kogo Y, Oguchi-Katayama A, Tomaru Y, et al: Rapid screening assay for KRASmutations by the modified smart amplification process. J Mol Diagn. 10:520–526. 2008. View Article : Google Scholar : PubMed/NCBI | |
Miyamae Y, Shimizu K, Mitani Y, Araki T, Kawai Y, Baba M, Kakegawa S, Sugano M, Kaira K, Lezhava A, et al: Mutation detection of epidermal growth factor receptor and KRASgenes using the smart amplification process version 2 from formalin-fixed, paraffin-embedded lung cancer tissue. J Mol Diagn. 12:257–264. 2010. View Article : Google Scholar : PubMed/NCBI | |
Krypuy M, Newnham GM, Thomas DM, Conron M and Dobrovic A: High resolution melting analysis for the rapid and sensitive detection of mutations in clinical samples: KRAS codon 12 and 13 mutations in non-small cell lung cancer. BMC Cancer. 6:2952006. View Article : Google Scholar : PubMed/NCBI | |
Tsiatis AC, Norris-Kirby A, Rich RG, Hafez MJ, Gocke CD, Eshleman JR and Murphy KM: Comparison of Sanger sequencing, pyrosequencing, and melting curve analysis for the detection of KRASmutations: Diagnostic and clinical implications. J Mol Diagn. 12:425–432. 2010. View Article : Google Scholar : PubMed/NCBI | |
Aubin F, Gill S, Burkes R, Colwell B, Kamel-Reid S, Koski S, Pollett A, Samson B, Tehfe M, Wong R, et al: Canadian Expert Group consensus recommendations: KRAS testing in colorectal cancer. Curr Oncol. 18:e180–e184. 2011. View Article : Google Scholar : PubMed/NCBI | |
Blons H, Rouleau E, Charrier N, Chatellier G, Côté JF, Pages JC, de Fraipont F, Boyer JC, Merlio JP, Morel A, et al MOKAECM Collaborative Group: Performance and cost efficiency of KRAS mutation testing for metastatic colorectal cancer in routine diagnosis: The MOKAECM study, a nationwide experience. PLoS One. 8:e689452013. View Article : Google Scholar : PubMed/NCBI | |
Ludyga N, Grünwald B, Azimzadeh O, Englert S, Höfler H, Tapio S and Aubele M: Nucleic acids from long-term preserved FFPE tissues are suitable for downstream analyses. Virchows Arch. 460:131–140. 2012. View Article : Google Scholar : PubMed/NCBI |