Open Access

Curative effect of artificial femoral head replacement and its effect on hip joint function and complications of senile patients with femoral intertrochanteric fracture

  • Authors:
    • Haiwei Shi
    • Long Xiao
    • Zhifang Wang
  • View Affiliations

  • Published online on: May 24, 2018     https://doi.org/10.3892/etm.2018.6214
  • Pages: 623-628
Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

Curative effect of artificial femoral head replacement on hip joint function and complications of elderly patients with femoral intertrochanteric fracture were investigated. Eighty patients who were operated for femoral intertrochanteric fractures operation were randomly divided into observation group (n=40) and control group (n=40). The observation group was treated with artificial femoral head replacement, while the control group received internal proximal femur locking plate fixation. In the observation group, the operation time was shorter than that in the control group (P<0.05). The intraoperative bleeding was less than that in the control group (P<0.05). The postoperative indwelling drainage time was shorter than that in the control group (P<0.05). Besides, at 3, 6 and 12 months after operation, 10 m walking speed in the observation group was significantly higher than that in the control group (P<0.05). The 5-time sit-stand time was shorter than that in the control group (P<0.05). At 1 week, 1 month, 3, 6 and 12 months after operation, Harris hip joint scores and visual analogue scale scores in the observation group were both superior to those in the control group (P<0.05). Moreover, the total hospitalization time in the observation group was shorter than that in the control group. Time of walking on crutches and walking without crutches was earlier than that in the control group (P<0.05). The overall proportion of postoperative chronic pain, thrombosis and failed surgery in the observation group was significantly lower than that in the control group (P<0.05). Finally, physical and psychological scores in the observation group after intervention were obviously higher than those in the observation group before intervention and the control group after intervention (P<0.05). Artificial femoral head replacement is characterized by the short operation time, less intraoperative bleeding, fast postoperative recovery of joint function, low degree of pain and fewer complications in the treatment of senile femoral intertrochanteric fracture, which can improve the postoperative life quality of patients.

Introduction

With the progress of socialization in China, the aging of population has been increasingly prominent. The elderly population is often accompanied with various medical diseases, especially in middle-aged women who are often accompanied with osteoporosis, so the slight trauma can lead to femoral intertrochanteric fracture easily (1). Intertrochanteric fractures in senile patients are mostly unstable fractures accompanied with osteoporosis, while the fractures are often comminuted, involving the large and small intertrochanteric fractures. Mostly the femoral distance was destroyed, resulting in the loss of its mechanical support, and even involving the proximal femoral medullary cavity. At present, surgery is the preferred treatment means for the disease to avoid venous thrombosis, malnutrition, bed sores and joint stiffness, caused by long-term immobilization (2). Although there are many surgical methods for the disease, such as internal fixation with multi-Kirschner wires, with Richard nail and Gamma nail and with dynamic hip screw (DHS) locking screw (3), they will cause larger trauma, it is hard for patients, especially the senile patients, to get out of bed early after operation, and postoperative complications, such as severe pain, occur, affecting the prognosis of patients (4).

Proximal femur locking plate (PFLP) is widely used for the treatment of proximal femoral fractures in recent years, which belongs to the extramedullary fixation system (5). The PFLP is reasonably designed and anatomically matches with the proximal epiphysis of the femur. It is able to fix the coronal plane fracture of the large as well as small intertrochanteric fracture, meeting the demands of intertrochanteric comminuted fracture fixation internally.

Artificial femoral head replacement is a relative simple operation with modeled procedures, which causes less trauma, and patients can get out of bed early after operation thus reducing the complications caused by long-term immobilization. Besides, patients could begin early hip exercise and walk with weight to quickly restore hip function to the preoperative state. Moreover, this operation could help to avoid many complications caused by internal fixation (6). Therefore, it is recommended as one of the preferred methods in the treatment of senile femoral intertrochanteric fracture (7). In this study, the experience of performing PFLP fixation as well as artificial femoral head replacement for the senile femoral intertrochanteric fracture in recent years was summarized and its clinical application effect is reported.

Patients and methods

General data

Eighty patients with femoral intertrochanteric fractures who received artificial femoral head replacement under intraspinal anesthesia in Zhangjiagang Hospital from May 2014 to December 2016 were selected. They were aged 60–85 years, and signed the informed consent for enrollment, operation and anesthesia. At the same time, this study was discussed and approved by the Medical Ethics Committee of Zhangjiagang Hospital of Traditional Chinese Medicine Affiliated to Nanjing University of Chinese Medicine (Zhangjiagang, China). Patients complicated with severe cardiopulmonary insufficiency, severe liver and kidney function deficiency, coagulation disorders, spinal deformity, malignant tumors, fractures in other parts of lower limbs or mental illness, or who used analgesia device after operation or refused to be enrolled were excluded. Patients enrolled were divided into two groups, the observation group (n=40) and the control group (n=40), using the random number method. In the observation group, there were 20 males and 20 females aged 60–85 years with an average of 73.5±1.3 years; in terms of injured part, there were 16 cases on the left and 24 cases on the right. Based on Evans-Jensen classification (8), 2 were in type I, 6 in type II, 15 in type III, 16 in type IV and 1 in type V. In the control group, there were 21 males and 19 females aged 60–85 years with an average of 73.6±1.3 years; in terms of injured part, there were 15 cases on the left and 25 cases on the right. Based on Evans-Jensen classification, 3 were in type I, 3 in type II, 16 in type III and 18 in type IV. The differences in sex, age and injured part and Evans-Jensen classification between the two groups were not statistically significant (P>0.05).

Methods

The observation group was treated with artificial femoral head replacement. The incision was entered using the Smith-Petersen method. All patients received the combined spinal-epidural anesthesia in a lateral position. A 8 cm-long incision was made in the greater trochanter of femur till 5 cm below the greater trochanter of femur, followed by blunt separation to fully expose the fracture site in greater trochanter of femur. The fracture re-displacement was avoided. The femoral head and labrum acetabulare were exposed, the lateral iliac artery was ligated and then the joint capsule was cut. The femoral neck was broken from 1.5 cm in the femoral lesser trochanter. The femoral head was removed, and the bone marrow was enlarged. The femoral prosthesis was placed into the fracture site of femur, and bound with wire after determining the location and stability. Then the prosthesis handle was removed, and the medullary cavity was filled with the bone cement. Then the prosthesis handle was placed once again at 15° forward; the excess bone cement was cleaned up. The control group was treated with PFLP fixation. First, a 20 cm-long longitudinal incision was made on the greater trochanter of femur, followed by blunt separation to expose the femoral membrane. Under the C-arm, the Kirschner wire was placed at approximately 5 cm under the greater trochanter. The Kirschner wire at an appropriate position under the femoral neck was used as the guide pin, and the cancellous bone screw was placed and the locking screws were screwed on.

Observational indexes

The elderly patients were all followed up for 12 months, and the relevant data were obtained through calling them or their guardians combined with outpatient follow-up. The relevant situations of operation, 10 m walking speed and 5-time sit-stand time at 3, 6 and 12 months after operation, Harris hip score before and after operation, pain at different time-points before and after operation, total hospitalization time, time of walking on crutches and walking without crutches, complications and 36-item short-form health survey questionnaire (SF-12) scores before and after intervention were compared between the two groups.

Evaluation criteria

The length of lower limbs was measured using the tape from iliac spine to inferior margin of medial malleolus. Those with difference in length of the lower limbs greater than 1.5 cm were diagnosed as length discrepancy of both lower limbs; the 10 m walking speed was based on the measurement of 10 m plane linear distance using the stopwatch, and the 5-time sit-stand time was based on the measurement using the knee-high back bench and stopwatch. The pain score was measured using the visual analogue scale (VAS); the highest score (10 points) indicated severe pain, while the lowest score (0 point) indicated no pain; the higher the score was, the more severe the pain was. Harris hip function score (0–100 points): >90 points indicated excellent and good, while >70 points indicated the hip joint dysfunction. SF-12 score (0–50 points): the patient's physical function and psychological function were scored at the same time; the higher the score was, the better the life quality was.

Statistical analysis

Statistical Product and Service Solutions (SPSS) 21.0 (IBM Corp., Armonk, NY, USA) was used for the statistical analysis. All measurement data in this study are presented as mean ± standard deviation, and all enumeration data are presented as percentage. t-test was used for the comparison of measurement data, while the Chi-square test was used for the comparison of enumeration data. One-way ANOVA test followed by post hoc test (Least Significant Difference) was performed for multiple comparisons between the groups. P<0.05 was considered to indicate a statistically significant difference.

Results

Comparison of relevant situations of operation between the two groups

In the observation group, the operation time was significantly shorter than that in the control group, the intraoperative bleeding was less than that in the control group (P<0.05), and the postoperative indwelling drainage time was significantly shorter than that in the control group (P<0.05) (Table I).

Table I.

Comparison of relevant situations of operation between the two groups (mean ± standard deviation).

Table I.

Comparison of relevant situations of operation between the two groups (mean ± standard deviation).

Operation time (min)Intraoperative bleeding (ml)Postoperative drainage time (days)
Observation group45.6±2.8103.5±10.52.1±0.2
Control group63.2±3.9256.8±23.93.3±0.3
t value23.18537.14121.049
P-value<0.001<0.001<0.001
Comparison of 10 m walking speed and 5-time sit-stand time at 3, 6 and 12 months after operation between the two groups

At 3 months after operation, the 10 m walking speed in the observation group was significantly higher than that in the control group (P<0.05), and the 5-time sit-stand time was shorter than that in the control group (P<0.05) (Table II).

Table II.

Comparison of 10 m walking speed and 5-time sit-stand time at 3, 6 and 12 months after operation between the two groups (mean ± standard deviation).

Table II.

Comparison of 10 m walking speed and 5-time sit-stand time at 3, 6 and 12 months after operation between the two groups (mean ± standard deviation).

3 months6 months12 months



10 m walking speed (m/sec)5-time sit-stand time (sec)10 m walking speed (m/sec)5-time sit-stand time (sec)10 m walking speed (m/sec)5-time sit-stand time (sec)
Observation group1.6±0.256.6±11.02.1±0.345.2±5.72.7±0.540.5±5.3
Control group0.7±0.173.0±13.11.6±0.253.1±4.52.3±0.348.6±3.1
t value25.4566.06420.1267.8223.325.69
P-value<0.001<0.0010.00230.00160.0150.025
Comparison of Harris hip scores before and after operation between the two groups

The Harris hip scores of the two groups before operation were 35.6±2.1 and 35.5±2.1 points, and there was no statistically significant difference (t=0.000; P>0.05). At 1 week, 1 month, 3, 6 and 12 months after operation, the Harris hip scores of the observation group were 49.6±3.1, 68.9±6.5, 85.6±7.2, 90.7±5.3 and 93.1±2.3 points, respectively, which were superior to those of the control group in the same period (40.3±2.6, 56.1±4.0, 70.3±5.0, 86.8±3.5 and 88.9±2.6 points) (t=14.537, 10.607, 11.039, 9.835, 12.117; P<0.05) (Fig. 1).

Comparison of VAS pain scores at different time-points before and after operation

The VAS pain scores of the two groups before operation were 7.5±0.3 and 7.5±0.4 points, and there was no statistically significant difference (t=0.213; P>0.05). At 1 week, 1 month, 3, 6 and 12 months after operation, the VAS pain scores of the observation group were 6.1±0.2, 2.5±0.2, 1.3±0.1, 0.8±0.4 and 0.5±0.2 points, respectively, which were superior to those of the control group in the same period (7.0±0.2, 5.6±0.3, 3.5±0.2, 1.6±0.3 and 1.2±0.2 points) (t=20.125, 54.378, 44.000, 32.236, 25.560; P<0.05) (Fig. 2).

Comparison of total hospitalization time and time of walking on crutches and walking without crutches between the two groups

The total hospitalization time in the observation group was shorter than that in the control group, and the time of walking on crutches and walking without crutches was earlier than that in the control group (P<0.05) (Table III).

Table III.

Comparison of total hospitalization time and time of walking on crutches and walking without crutches between the two groups (days, mean ± standard deviation).

Table III.

Comparison of total hospitalization time and time of walking on crutches and walking without crutches between the two groups (days, mean ± standard deviation).

Total hospitalization timeTime of walking on crutchesTime of walking without crutches
Observation group14.6±0.810.2±0.396.3±8.5
Control group16.5±1.115.6±0.9158.6±11.4
t value14.57236.00027.709
P-value<0.001<0.001<0.001
Comparison of complications between the two groups

The proportions of postoperative chronic pain, failed operation (including prosthesis or internal fixation loose and nonunion) in the observation group were significantly lower than those in the control group (P<0.05) (Table IV).

Table IV.

Comparison of complications between the two groups (n, %).

Table IV.

Comparison of complications between the two groups (n, %).

Postoperative chronic painFailure of operationTotal incidence rate
Observation group123 (7.5%)
Control group3811 (27.5%)
χ2 4.242
P-value 0.039
Comparison of SF-12 scores between the two groups before and after intervention

In SF-12 scores, the physical score and psychological score in the two groups before intervention were 23.1±1.7, 18.9±1.5 and 23.2±1.7, 18.8±1.5 points, respectively, and there were no statistically significant differences (t=0.263 and 0.298; P>0.05). After intervention, the physical score and psychological score in the observation group were 43.5±2.3 and 40.8±2.0 points, respectively, which were obviously higher than those in the observation group before intervention (t=45.111 and 55.403; P<0.05) and the control group after intervention (38.6±2.1 and 35.6±1.9 points) (t=9.950 and 11.923; P<0.05) (Fig. 3).

Comparison of X-ray between the two groups before and after intervention

Preoperative and postoperative X-ray comparison of two groups of patients are shown in Fig. 4 (A and B represent the preoperative and postoperative X-ray of the observation group; C and D represent the preoperative and postoperative X-ray of the control group).

Discussion

Femoral intertrochanteric fracture is a kind of common fracture in skeletal system in the elderly, which is mainly based on osteoporosis. The pathological fracture will be caused under the action of external forces, or even slight forces. If there is no timely and effective treatment, the mortality rate will be significantly increased (9). The key in the successful treatment of this disease is the choice of surgical method and surgical techniques (10). The surgical treatment of senile femoral intertrochanteric fracture mainly aims to promote the recovery of autonomic activities of patients to throw away the crutches as soon as possible (11) and reduce the complications caused by long-term immobilization (12). Therefore, the treatment of this disease should be targeted: i) strong internal fixation; ii) early and safe activities; iii) less surgical trauma and short operative time; iv) better functional recovery after surgery, so the surgical treatment within 48 h is recommended if medical conditions permit.

Proximal femoral locking plate is designed based on the anatomy of the proximal femur (5). Due to the locking function of its screw thread in distance and depth as well as the locking function of screw tail, the screw could lock the plate hole to fix the fracture. At the same time, the plate and screw can be fixed through the thread, making the locking plate a whole part, so that the fracture could be fixed on the ‘surface’, which could avoid stress concentration and enhance the capacity of anti-rotation and internal fixation. It is applied to the senile intertrochanteric fracture combined with osteoporosis (13). The PFLP surgery does not require shaping to make the large intertrochanteric fractures and the small intertrochanteric fractures to be well fixed. The upper end of the plate consists of 3 cancellous bone locking screws, which can effectively prevent the occurrence of hip varus and maintain the stability of the broken end. The PFLP is easy to operate and has a good short-term efficacy, allowing early activity. The 40 cases of the control group in our study had good effect overall, while the follow-up Harris hip function score, VAS score and SF-12 were improved compared with those of preoperative conditions. However, there were 8 cases (20%) of internal fixation loosening and nonunion in the treatment of PFLP, which might be related to the blood supply and the seriousness of osteoporosis in elderly patients.

Jin et al have shown that the failure rate of internal fixation of 8–16% in the unstable intertrochanteric fracture (14). Therefore, it is suggested by some researchers that treatment of artificial joint replacement should be adopted for femoral intertrochanteric fractures in special populations (15). This method allows immediate and effective recovery of the function of the hip joint while the patients could resume the weight-bearing function as soon as possible, making them leave the bed early and shortening the bed rest time. The patients get good recovery of their limb function and quality of life is improved as well. Furthermore, the artificial joint replacement could avoid hip varus deformity, failure of internal fixation and complications caused by long-term immobilization (16). Babst et al demonstrated that we should not simply rely on some strong internal fixtures, but also should pay attention to the reset. The ideal reset could stabilize the fracture, however, on this basis the internal fixation will increase its own strength (17). Compared with the artificial femoral head replacement, the proximal femoral locking plate fixation would cause larger surgical trauma, more surgical field exposure and more surgical bleeding to achieve a better reset, which exerts greater impact on the organ function of patients. In contrast, the observation group in our study experienced short surgery time, less bleeding and fast postoperative recovery. Moreover, the total hospitalization time of the observation group was shorter than that of the control group; the walking time with the crutches and the time taken for walking without crutches were both earlier in the observational group than in the control group, which were conducive for early functional activities in patients and reduced complications caused by long-term immobilization.

Postoperative follow-up showed that the Harris hip score of the observation group was better than the control group, while the pain VAS score was lower than the control group. In addition, the comparisons of SF-12 scores between the two groups before and after intervention revealed that in SF-12 scores, the physical score and psychological score in the observation group after intervention were obviously superior to those in the observation group before intervention and the control group after intervention, which further indicated that artificial femoral head replacement in the treatment of senile femoral intertrochanteric fracture has a positive significance in improving the overall life quality of patients after operation. Moreover, the stable artificial femoral head replacement can make patients get out of bed and bear load earlier after operation (18). At the same time, it avoids the pain caused by secondary internal fixation, and improves patients' confidence and compliance (19). It is particularly suitable for the senile (18) and unstable fractures (20,21), and those with obvious osteoporosis and old fractures receiving failed conventional internal fixation (22).

In conclusion, artificial femoral head replacement is characterized by the short operation time, less intraoperative bleeding, fast postoperative recovery of joint function, low degree of pain and fewer complications caused by long-term immobilization, which can improve the postoperative life quality of patients. It has a good clinical efficacy in the treatment of senile femoral intertrochanteric fractures. At the same time, the orthopedic surgeon should take full account of the patient's age, type of fracture, bone quality, with or without other medical diseases and economic conditions in the face of elderly patients with intertrochanteric fractures, select the appropriate treatment to minimize patients pain and to achieve rapid recovery.

Acknowledgements

Not applicable.

Funding

No funding was received.

Availability of data and materials

All data generated or analyzed during this study are included in this published article.

Authors' contributions

HS designed the study. LX and ZW were responsible for data collection and analysis. ZW performed the operations. HS prepared the manuscript. All authors read and approved the final manuscript.

Ethics approval and consent to participate

This study was approved by the Ethics Committee of Zhangjiagang Hospital of Traditional Chinese Medicine Affiliated to Nanjing University of Chinese Medicine (Zhangjiagang, China). Signed informed consents were obtained from the patients or guardians.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

References

1 

Peng MJ, Chen HY, Hu Y, Ju X and Bai B: Finite element analysis of porously punched prosthetic short stem virtually designed for simulative uncemented hip arthroplasty. BMC Musculoskelet Disord. 18:2952017. View Article : Google Scholar : PubMed/NCBI

2 

Khanna R, Kokubo T, Matsushita T and Takadama H: Fabrication of dense α-alumina layer on Ti-6Al-4V alloy hybrid for bearing surfaces of artificial hip joint. Mater Sci Eng C. 69:1229–1239. 2016. View Article : Google Scholar

3 

Zhang BL, Wang F, Tian MB, Yin WL, You XY, Li D, Ma LG and Xing LQ: Articular capsule repair in initial artificial hip replacement via anterolateral approach to the hip joint. J Biol Regul Homeost Agents. 30:441–447. 2016.PubMed/NCBI

4 

Lin YT, Wu JS and Chen JH: The study of wear behaviors on abducted hip joint prostheses by an alternate finite element approach. Comput Methods Programs Biomed. 131:143–155. 2016. View Article : Google Scholar : PubMed/NCBI

5 

Fankhauser F, Boldin C, Schippinger G, Haunschmid C and Szyszkowitz R: A new locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res. 430:176–181. 2005. View Article : Google Scholar

6 

Hsu CJ, Chou WY, Chiou CP, Chang WN and Wong CY: Hemi-arthroplasty with supplemental fixation of greater trochanter to treat failed hip screws of femoral intertrochanteric fracture. Arch Orthop Trauma Surg. 128:841–845. 2008. View Article : Google Scholar : PubMed/NCBI

7 

Li N, Liu HN, Gong XF, Zhu SW, Wu XB and He L: Epidemiological analysis of hospitalized patients with femoral neck fracture in a first-class hospital of Beijing. Beijing Da Xue Xue Bao Yi Xue Ban. 48:292–296. 2016.(In Chinese). PubMed/NCBI

8 

Jensen JS and Michaelsen M: Trochanteric femoral fractures treated with McLaughlin osteosynthesis. Acta Orthop Scand. 46:795–803. 1975. View Article : Google Scholar : PubMed/NCBI

9 

Richmond J, Aharonoff GB, Zuckerman JD and Koval KJ: Mortality risk after hip fracture. J Orthop Tauma. 17:2–5. 2003. View Article : Google Scholar

10 

van Embden D, Rhemrev SJ, Meylaerts SA and Roukema GR: The comparison of two classifications for trochanteric femur fractures: the AO/ASIF classification and the Jensen classification. Injury. 41:377–381. 2010. View Article : Google Scholar : PubMed/NCBI

11 

Khanna R, Kokubo T, Matsushita T, Nomura Y, Nose N, Oomori Y, Yoshida T, Wakita K and Takadama H: Novel artificial hip joint: A layer of alumina on Ti-6Al-4V alloy formed by micro-arc oxidation. Mater Sci Eng C. 55:393–400. 2015. View Article : Google Scholar

12 

Clarke A, Pulikottil-Jacob R, Grove A, Freeman K, Mistry H, Tsertsvadze A, Connock M, Court R, Kandala NB, Costa M, et al: Total hip replacement and surface replacement for the treatment of pain and disability resulting from end-stage arthritis of the hip (review of technology appraisal guidance 2 and 44): Systematic review and economic evaluation. Health Technol Assess. 19:1–668. 2015. View Article : Google Scholar

13 

Konstantinidis L, Papaioannou C, Mehlhorn A, Hirschmüller A, Südkamp NP and Helwig P: Salvage procedures for trochanteric femoral fractures after internal fixation failure: biomechanical comparison of a plate fixator and the dynamic condylar screw. Proc lnst Mech Eng H. 225:710–717. 2011. View Article : Google Scholar

14 

Jin WJ, Dai LY, Cui YM, Zhou Q, Jiang LS and Lu H: Reliability of classification systems for intertrochanteric fractures of the proximal femur in experienced orthopaedic surgeons. Injury. 36:858–861. 2005. View Article : Google Scholar : PubMed/NCBI

15 

Hwang DS, Kwak SK and Woo SM: Results of cementless hemiarthroplasty for elderly patients with unstable intertrochanteric fractrres. J Korean Hip Soc. 16:386–391. 2004.

16 

Chan KC and Gill GS: Cemented hemiarthroplasties for elderly patients with intertrochanteric fractures. Clin Orthop Relat Res. 371:206–215. 2000. View Article : Google Scholar

17 

Babst R, Renner N, Biedermann M, Rosso R, Heberer M, Harder F and Regazzoni P: Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures. J Orthop Trauma. 12:392–399. 1998. View Article : Google Scholar : PubMed/NCBI

18 

Feng W, Hao T, Liu WL, Jia YF, Hao ZT and Bai SB: Clinical outcome of endoprosthetic replacement for failed treatment of intertrochanteric fractures: A retrospective case series. Pak J Med Sci. 29:633–637. 2013. View Article : Google Scholar : PubMed/NCBI

19 

Lizhang J, Taylor SD, Jin Z, Fisher J and Williams S: Effect of clearance on cartilage tribology in hip hemi-arthroplasty. Proc Inst Mech Eng H. 227:1284–1291. 2013. View Article : Google Scholar : PubMed/NCBI

20 

Suzuki A, Koshida K and Matsubara K: Adjustment of overestimated CT-based attenuation correction on bone SPECT/CT after hip-resurfacing arthroplasty. J Nucl Med Technol. 41:203–207. 2013. View Article : Google Scholar : PubMed/NCBI

21 

Figved W, Dahl J, Snorrason F, Frihagen F, Röhrl S, Madsen JE and Nordsletten L: Radiostereometric analysis of hemiarthroplasties of the hip - a highly precise method for measurements of cartilage wear. Osteoarthritis Cartilage. 20:36–42. 2012. View Article : Google Scholar : PubMed/NCBI

22 

Yu X, Jiang W, Pan Q, Wu T, Zhang Y, Zhou Z and Du D: Umbrella-shaped, memory alloy femoral head support device for treatment of avascular osteonecrosis of the femoral head. Int Orthop. 37:1225–1232. 2013. View Article : Google Scholar : PubMed/NCBI

Related Articles

Journal Cover

August-2018
Volume 16 Issue 2

Print ISSN: 1792-0981
Online ISSN:1792-1015

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Shi H, Xiao L and Wang Z: Curative effect of artificial femoral head replacement and its effect on hip joint function and complications of senile patients with femoral intertrochanteric fracture. Exp Ther Med 16: 623-628, 2018.
APA
Shi, H., Xiao, L., & Wang, Z. (2018). Curative effect of artificial femoral head replacement and its effect on hip joint function and complications of senile patients with femoral intertrochanteric fracture. Experimental and Therapeutic Medicine, 16, 623-628. https://doi.org/10.3892/etm.2018.6214
MLA
Shi, H., Xiao, L., Wang, Z."Curative effect of artificial femoral head replacement and its effect on hip joint function and complications of senile patients with femoral intertrochanteric fracture". Experimental and Therapeutic Medicine 16.2 (2018): 623-628.
Chicago
Shi, H., Xiao, L., Wang, Z."Curative effect of artificial femoral head replacement and its effect on hip joint function and complications of senile patients with femoral intertrochanteric fracture". Experimental and Therapeutic Medicine 16, no. 2 (2018): 623-628. https://doi.org/10.3892/etm.2018.6214