Evaluation of the impact of linked color imaging for improving the visibility of colonic polyp
- Authors:
- Published online on: September 24, 2019 https://doi.org/10.3892/ol.2019.10917
- Pages: 5555-5560
Abstract
Introduction
Colonoscopy is the criterion standard technique for identification of colonic neoplasia, and resection of colorectal adenomas is the most effective method for preventing colorectal cancer (1). Improved endoscopic procedures with higher rates of adenoma detection may improve the efficacy of colonoscopy for preventing cancer (1–3). Chromoendoscopy, which was implemented in the 1980s, has improved identification of small and flat colorectal lesions, and several randomized controlled trials have demonstrated significantly better rates of small neoplastic lesion detection by pan-colonic chromoendoscopy compared with conventional colonoscopy (4,5). However, performing total colonic dye-spraying endoscopy requires a certain degree of endoscopic skills and longer extubation compared with conventional colonoscopy (6). The use of narrow-band imaging (NBI), which applies short-wavelength light to enabling detection of the absorbance spectrum of hemoglobin, during colonoscopy is expected to enhance adenoma detection without prolonging the extubation period (7). However, the ability of first-generation NBI systems to increase adenoma detection has not been demonstrated, considering that intestinal fluids such as bile appear red in color, like blood, and that the luminal brightness is lower in NBI than in conventional colonoscopy (8). To offset these constraints, blue laser imaging (BLI), which utilizes narrow-band laser light combined with white laser light, was developed. However, the brightness of BLI is still not adequate for detecting distant lesions (9).
Linked color imaging (LCI) is a novel endoscopic system developed by Fujifilm Co. that increases color contrast by utilizing short-wavelength narrow-band laser light combined with white laser light on the basis of BLI technology (9). Unlike BLI and NBI, the luminal brightness of LCI is not impaired compared with that of conventional colonoscopy, even at a distant view; consequently, LCI may improve the visibility of colonic neoplasms (10,11). However, thus far, the extent to which LCI improves the visibility of colonic polyps has not been clarified quantitatively. Therefore, in this study, we evaluated the color differences between colonic polyps and their surrounding mucosa and compared the color differences among conventional colonoscopy, BLI, LCI, and chromoendoscopy.
Patients and methods
Endoscopic procedure
This was a retrospective single-center study. Between December 2016 and May 2017, all patients who received a total colonoscopy at the Inoue Gastroenterology and Endoscopy Clinic were recruited. The Ethics Committee of Osaka Medical College approved this study, and written informed consent was waived because of the retrospective design. For the endoscopic procedures, signed informed consent was obtained from the patients. The inclusion criteria were as follows: i) surveillance colonoscopy of known colorectal adenomas or cancer; ii) screening colonoscopy in patients with positive fecal occult blood; and iii) diagnostic colonoscopy in patients with symptoms, such as rectal bleeding, abdominal pain, and change in bowel habits. Patients with inadequate bowel preparation, colitis, and melanosis did not enter the study. For each polyp identified, pictures with three different color images (WL, BLI, and LCI) for the same lesion and from the same point of view were selected for evaluation. Among the selected pictures, those of chromoendoscopy for the same lesion and from the same point of view were also used for evaluation. In the case of magnified colonoscopic images, high magnification (×80) pictures with three different color images for the same lesion and from the same point of view were selected for evaluation. Colonoscopy was conducted using the LASEREO system (FUJIFILM) with an EC-L600ZP endoscope. Endoscopy was performed using the WL, BLI, and LCI modalities. All endoscopic images were stored in JPEG format. An experienced endoscopist (T.I.) performed the endoscopic procedures and selection of the images, and an experienced pathologist (Y.E.) examined all resected tissues.
Calculation of the color difference
The color difference (ΔE) was calculated using the CIELAB color space, a three-dimensional color space that comprises a black-white axis (L*), a red-green axis (a*), and a yellow-blue axis (b*) and that associates color perception with colorimetric values. L* is defined as lightness, a* as the red-green component, and b* as the yellow-blue component (12). ΔE between a polyp (p) and the surrounding mucosa (b) was calculated according to the following formula: ΔEpb=(Lp-Lb)2+(ap-ab)2+(bp-bb)2. According to Sato et al, we determined the L*a*b* values (13). Briefly, this was done as follows: i) the corresponding regions [for non-magnified images, the polyp and surrounding mucosa, 64 pixels each (Fig. 1), and for magnified images, the vessel and non-vessel areas, 9 pixels each (Fig. 2)] were selected on WL, BLI, and LCI images using Adobe Photoshop Elements 15; ii) the median RGB value was determined; and iii) the L*a*b* value was calculated from the average of the RGB values.
Statistical analysis
Statistical analyses were conducted using Stat View software, version 5.0 (SAS Institute, Inc.). All data are expressed as means ± standard deviation. One-way analysis of variance was performed for multiple comparisons, followed by Fisher's exact test. P-values of less than 0.05 were considered to be statistically significant.
Results
Color differences in non-magnified images
From December 2016 to May 2017, 64 patients with 114 polyps were enrolled in this study. Among these polyps, 113 (64 patients) and 95 (53 patients) were assessed for color differences in non-magnified and magnified (×80) images, respectively (Table I). The overall ΔE was significantly increased with LCI and chromoendoscopy compared with WL and BLI. The ΔE values were 11.0±6.6, 10.7±7.0, 15.1±9.3, and 14.8±7.2 for WL, BLI, LCI, and chromoendoscopy, respectively (Fig. 3). L*, which represents the lightness of a color, was significantly reduced by BLI compared with WL, LCI, and chromoendoscopy (54.8±8.4, 47.7±9.7, 58.5±8.8, and 51.7±9.4 for WL, BLI, LCI, and chromoendoscopy, respectively) (Fig. 4). The ΔE values of all neoplastic lesions (adenoma and cancer) were increased by LCI compared with WL, BLI, and chromoendoscopy. On the other hand, the ΔE values of the non-neoplastic lesions were enhanced by chromoendoscopy compared with WL, BLI, and LCI, although the differences were not significant (Fig. 5). Regarding the effect of lesion size, LCI increased the ΔE of neoplastic polyps in not only large (more than 6 mm in diameter) but also small (less than 6 mm) lesions (Fig. 6). These findings suggest that LCI enhances the visibility of polyps, especially neoplastic polyps, even though they are small lesions, without impairing the lightness of the color.
Color differences in magnified images
Using magnified pictures of polyps, we calculated color differences between the vessel and non-vessel areas in the WL, BLI, and LCI images. The ΔE was 12.2±5.6, 16.1±5.5, and 20.6±9.2 for WL, BLI, and LCI, respectively. Overall, ΔE was significantly increased in BLI and LCI images compared with that in WL images. BLI and LCI also had a significantly increased ΔE in magnified images of neoplastic polyps (Fig. 7). These results indicate that BLI and LCI are useful in magnifying colonoscopy for diagnosis of colonic polyps.
Discussion
To our knowledge, this is the first reported quantitative evaluation of the degree to which LCI enhances colonic polyp visibility. The results of this study revealed that LCI, compared with WL and BLI, significantly increased the color difference between polyps and their corresponding surrounding mucosa, without impairing luminal brightness. In particular, LCI significantly enhanced the visibility of neoplastic lesions, regardless of their size, but not non-neoplastic lesions, such as hyperplastic polyps and sessile serrated adenoma/polyps (SSA/P).
Considering that resection of polyps using colonoscopy has been reported to prevent the occurrence of colorectal cancer dramatically, by 76–90%, colonoscopy is considered to be the most effective tool for colon cancer prevention (2). However, 17–24% of adenomas may be missed during colonoscopic examination (13,14). Therefore, improved endoscopic methods that can accurately detect adenomas have been sought. Thus far, pan-colonic chromoendoscopy has been reported to increase the detection of small neoplastic lesions significantly, with significantly prolonged extubation times (6,15,16). Since the NBI system was proposed for use during colonoscopy, several studies have been conducted to investigate the effect of NBI on improving the detection of colonic polyps (8). However, in these studies using first-generation NBI, it was not shown that NBI improves the adenoma detection rate compared with WL endoscopy (8). The reasons why these studies failed are considered to be related to the characteristics of NBI. For example, on NBI colonoscopy, intestinal fluids such as bile appear reddish, like blood, and the luminal brightness is reduced compared with that of conventional colonoscopy (7). Recently, a new-generation NBI system, which produces a twofold brighter image than the previous system, was reported to improve colonic polyp visibility and detection (17). Another novel image enhanced endoscopy (IEE) system, BLI, which enables one to obtain brighter images similar to new-generation NBI via the use of two different lasers creating white light illumination and short wavelength narrow-band light observation, was also revealed to improve the visibility of colorectal polyps (18,19). However, thus far, the extent to which these IEE systems improve the visibility of colonic polyps has not been evaluated quantitatively.
Interestingly, in this study, LCI, but not BLI, quantitatively improved the visibility of colonic polyps; the corresponding surrounding mucosa was darker using BLI compared with that using WL and LCI. These results suggest that BLI still cannot provide enough luminal brightness to improve the color difference between colonic polyps and their corresponding surrounding mucosa, even though BLI creates brighter images than the old-generation IEE system. Therefore, we suggest that LCI is most suitable for routine colonoscopic examination for colonic polyp detection.
In the case of magnifying observation, BLI and LCI provided a significant color difference between the vessel and non-vessel (surface) area. It is well known that pit pattern analysis via magnifying chromoendoscopy is an accurate diagnostic method for the differentiation of colorectal lesions. Recently, several studies found that BLI magnification is accurate enough to diagnose most colorectal polyps (20,21). Thus, the results regarding magnified images using BLI in this study confirm the results of those previous reports. We suggest that LCI is also useful for magnifying observation.
This study has some limitations. First, obtaining exact same timing of the three different color images (WL, BLI, and LCI) for the same lesion is impossible because of time lags. Second, this was a single-center retrospective study, and the number of samples was small. Moreover, all endoscopic procedures and selection of the images were performed by the same endoscopist. Third, because BLI uses a narrow wavelength range to provide information about microvessels, the color difference calculation using the CIELAB color space might not reflect the visibility of colonic polyps exactly. Therefore, a larger sample size may be required to determine the efficacy of LCI in improving the visibility of non-neoplastic polyps including SSA/P.
In conclusion, LCI significantly improved the visibility of colonic polyps irrespective of the size of the lesion, without impairing the brightness of the color, and LCI and BLI significantly improved the color differences in the magnified images of neoplastic polyps. These outcomes support the routine use of LCI for colonic polyp detection and of BLI for improving magnifying observations of the colonic polyps detected by LCI. In this study, LCI did not influence color differences in non-neoplastic lesions, such as hyperplastic polyps and SSA/P. Considering that SSA/P was recently recognized to have a similar malignant potential as that of traditional adenoma, further investigation is needed.
Acknowledgements
This abstract was presented at the 2018 Digestive Disease Week in Washington, DC, USA and was published in Gastrointestinal Endoscopy 2018; 87 (6S): AB485.
Funding
No funding was received.
Availability of data and materials
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Authors' contributions
YT performed the data collection and procedures; TI and KaK wrote the manuscript and analyzed the data. TI also contributed to drafting conception and design; KN, HT, YH, TO, SN, KeK and TT participated in collecting the data; YE and KH contributed to the interpretation of the data and supervised the study. All authors have read and approved the final manuscript.
Ethics approval and consent to participate
The present study was approved by the Ethics Review Committee of Osaka Medical College (approval no. 2429). Due to the retrospective design of the current study and patient anonymization, the review board determined that informed consent was not required.
Patient consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
References
Winawer SJ and Zauber AG: Colonoscopic polypectomy and the incidence of colorectal cancer. Gut. 48:753–754. 2001. View Article : Google Scholar : PubMed/NCBI | |
Winawer SJ, Zauber AG, Ho MN, O'Brien MJ, Gottlieb LS, Sternberg SS, Waye JD, Schapiro M, Bond JH, Panish JF, et al: Prevention of colorectal cancer by colonoscopic polypectomy. The national polyp study workgroup. N Engl J Med. 329:1977–1981. 1993. View Article : Google Scholar : PubMed/NCBI | |
Kaminski MF, Wieszczy P, Rupinski M, Wojciechowska U, Didkowska J, Kraszewska E, Kobiela J, Franczyk R, Rupinska M, Kocot B, et al: Increased rate of adenoma detection associates with reduced risk of colorectal cancer and death. Gastroenterology. 153:98–105. 2017. View Article : Google Scholar : PubMed/NCBI | |
Tada M, Katoh S, Kohli Y and Kawai K: On the dye spraying method in colonofiberscopy. Endoscopy. 8:70–74. 1977. View Article : Google Scholar : PubMed/NCBI | |
Tada M and Kawai K: Research with the endoscope: New techniques using magnification and chromoscopy. Clin Gastroenterol. 15:417–437. 1986.PubMed/NCBI | |
Brooker JC, Saunders BP, Shah SG, Thapar CJ, Thomas HJ, Atkin WS, Cardwell CR and Williams CB: Total colonic dye-spray increases the detection of diminutive adenomas during routine colonoscopy: A randomized controlled trial. Gastrointest Endosc. 56:333–338. 2002. View Article : Google Scholar : PubMed/NCBI | |
Inoue T, Murano M, Murano N, Kuramoto T, Kawakami K, Abe Y, Morita E, Toshina K, Hoshiro H, Egashira Y, et al: Comparative study of conventional colonoscopy and pan-colonic narrow-band imaging system in the detection of neoplastic colonic polyps: A randomized, controlled trial. J Gastroenterol. 43:45–50. 2008. View Article : Google Scholar : PubMed/NCBI | |
Ng SC and Lau JY: Narrow-band imaging in the colon: Limitations and potentials. J Gastroenterol Hepatol. 26:1589–1596. 2011. View Article : Google Scholar : PubMed/NCBI | |
Okada M, Sakamoto H, Takezawa T, Hayashi Y, Sunada K, Lefor AK and Yamamoto H: Laterally spreading tumor of the rectum delineated with linked color imaging technology. Clin Endosc. 49:207–208. 2016. View Article : Google Scholar : PubMed/NCBI | |
Yoshida N, Naito Y, Murakami T, Hirose R, Ogiso K, Inada Y, Dohi O, Kamada K, Uchiyama K, Handa O, et al: Linked color imaging improves the visibility of colorectal polyps: A video study. Endosc Int Open. 5:E518–E525. 2017. View Article : Google Scholar : PubMed/NCBI | |
Min M, Deng P, Zhang W, Sun X, Liu Y and Nong B: Comparison of linked color imaging and white-light colonoscopy for detection of colorectal polyps: A multicenter, randomized, crossover trial. Gastrointest Endosc. 86:724–730. 2017. View Article : Google Scholar : PubMed/NCBI | |
Sato Y, Sagawa T, Hirakawa M, Ohnuma H, Osuga T, Okagawa Y, Tamura F, Horiguchi H, Takada K, Hayashi T, et al: Clinical utility of capsule endoscopy with flexible spectral imaging color enhancement for diagnosis of small bowel lesions. Endosc Int Open. 2:E80–E87. 2014. View Article : Google Scholar : PubMed/NCBI | |
Rex DK, Cutler CS, Lemmel GT, Rahmani EY, Clark DW, Helper DJ, Lehman GA and Mark DG: Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies. Gastroenterology. 112:24–28. 1997. View Article : Google Scholar : PubMed/NCBI | |
Bensen S, Mott LA, Dain B, Rothstein R and Baron J: The colonoscopic miss rate and true one-year recurrence of colorectal neoplastic polyps. Polyp prevention study group. Am J Gastroenterol. 94:194–199. 1999. View Article : Google Scholar : PubMed/NCBI | |
Hurlstone DP, Cross SS, Slater R, Sanders DS and Brown S: Detecting diminutive colorectal lesions at colonoscopy: A randomised controlled trial of pan-colonic versus targeted chromoscopy. Gut. 53:376–380. 2004. View Article : Google Scholar : PubMed/NCBI | |
Le Rhun M, Coron E, Parlier D, Nguyen JM, Canard JM, Alamdari A, Sautereau D, Chaussade S and Galmiche JP: High resolution colonoscopy with chromoscopy versus standard colonoscopy for the detection of colonic neoplasia: A randomized study. Clin Gastroenterol Hepatol. 4:349–354. 2006. View Article : Google Scholar : PubMed/NCBI | |
Ogiso K, Yoshida N, Siah KT, Kitae H, Murakami T, Hirose R, Inada Y, Dohi O, Okayama T, Kamada K, et al: New-generation narrow band imaging improves visibility of polyps: A colonoscopy video evaluation study. J Gastroenterol. 51:883–890. 2016. View Article : Google Scholar : PubMed/NCBI | |
Yoshida N, Hisabe T, Hirose R, Ogiso K, Inada Y, Konishi H, Yagi N, Naito Y, Aomi Y, Ninomiya K, et al: Improvement in the visibility of colorectal polyps by using blue laser imaging (with video). Gastrointest Endosc. 82:542–549. 2015. View Article : Google Scholar : PubMed/NCBI | |
Togashi K, Nemoto D, Utano K, Isohata N, Kumamoto K, Endo S and Lefor AK: Blue laser imaging endoscopy system for the early detection and characterization of colorectal lesions: A guide for the endoscopist. Therap Adv Gastroenterol. 9:50–56. 2016. View Article : Google Scholar : PubMed/NCBI | |
Nakano A, Hirooka Y, Yamamura T, Watanabe O, Nakamura M, Funasaka K, Ohno E, Kawashima H, Miyahara R and Goto H: Comparison of the diagnostic ability of blue laser imaging magnification versus pit pattern analysis for colorectal polyps. Endosc Int Open. 5:E224–E231. 2017. View Article : Google Scholar : PubMed/NCBI | |
Yoshida N, Yagi N, Inada Y, Kugai M, Okayama T, Kamada K, Katada K, Uchiyama K, Ishikawa T, Handa O, et al: Ability of a novel blue laser imaging system for the diagnosis of colorectal polyps. Dig Endosc. 26:250–258. 2014. View Article : Google Scholar : PubMed/NCBI |