Augmentation of transgenic expression by ultrasound‑mediated liposome microbubble destruction
- Authors:
- Published online on: January 25, 2012 https://doi.org/10.3892/mmr.2012.766
- Pages: 964-970
Abstract
Introduction
Gene therapy has a broad application prospect in the treatment of cancer and genetic diseases, but its application is limited by the potential danger of virus vectors or the low transfection efficiency of non-virus vectors (1,2). To enhance the transgenic expression of the non-viral gene transfer system, the transgenic technology of ultrasound-mediated gene transfection may be applied (3–6). Microbubbles, which act as contrast agents for medical ultrasound imaging, could improve the transfection efficiency (7–11). Furthermore, microbubbles excited by ultrasound exposure may temporarily ‘open’ the cell membranes of nearby cells allowing plasmid DNA to be delivered into cells. Subsequently, the cells could reseal themselves and maintain their vitality (12).
While liposomes have a very low immunogenicity, liposome microbubbles (LMs) are a research hotspot that has developed rapidly in recent years, which is capable of targeting increasing specific drug treatment or gene transfection (7,13–17). However, a number of factors could affect the transfection efficiency, including the ultrasonic intensity, the duration of ultrasound treatment and the microbubble concentration. Although the application of sonoporation has been optimized in certain studies, the delivery of drugs is often difficult to control and has been observed in a number of cases to have numerous unwanted side effects. Proteins with high wavelength emission spectra, including red fluorescent protein (RFP), may be a better choice as a reporter gene (18). However, few cases exist in the literature regarding in vitro and in vivo optimization using an RFP reporter gene. The effects of LM on transgenic expression have not been systematically assessed, and the applications of ultrasound-mediated liposome microbubble destruction (UMLMD) have not yet been optimized. However, we suggest this technique effectively transfers genes. In previous experiments (19,20), a significant problem arose from the application of the non-viral gene transfer system of UMLMD. However, this UMLMD technique has not been studied thus far as a delivery system.
For this reason, we established a method that is cost-effective and safer than viral carrier gene therapy. The present study utilized the method of UMLMD to examine the transfection efficiency and safety of RFP in vivo and in vitro, while assessing the safety and efficacy of UMLMD. Our purpose was to obtain optimal transgenic expression with the lowest cell or tissue injury, in order to lay the foundation for efficient, targeted and non-invasive gene therapy.
Materials and methods
Cell culture
HeLa cells were obtained from the China Center for Type Culture Collection (CCTCC) and incubated in Dulbecco’s modified Eagle’s medium (DMEM, Gibco, Grand Island, NY, USA) with 10% fetal bovine serum (FBS, Gibco), 100 U/ml penicillin and 100 μg/ml streptomycin at 37°C in a humidified environment of 5% CO2/95% air. The total cell count was determined using a hemocytometer (Burker Turk, The Netherlands). The initial cell viability was determined by exclusion with trypan blue dye (Sigma-Aldrich, St. Louis, MO, USA). Exponentially growing cells were used in all experiments.
Plasmid DNA
The expression vector for the RFP gene plasmid (pDsRed-Express, Clontech, BD Biosciences, Billerica, MA, USA) had an excitation and emission maxima occurring at 557 nm and 579 nm, respectively. The plasmid DNA was obtained from DH5α Escherichia coli (Invitrogen, Carlsbad, CA, USA) and was prepared using a Qiaquick kit (Qiagen, Crawley, UK) according to the manufacturer’s instructions. The absorbance ratio at the wavelength of 260–280 nm for the plasmid DNA solution was measured to be between 1.8 and 2.0.
Preparation of LMs
LMs were kindly provided by the Department of Ultrasonography of Xinqiao Hospital, The Third Military Medical University, Chongqing, China. The LMs were prepared using mechanical agitation. The activation device was refitted from an amalgamator (ST-D, Beijing AT&M Biomaterials Co., Ltd, Beijing, China) at a calibration rate of (4,500±100) oscillations/min for 45 sec, using a reciprocating motion and an oscillation amplitude of (15±1) mm.
In vitro studies
Experimental apparatus
In vitro experiments were performed in an exposure water tank. The tank contained deionized water with an ultrasound transducer (Accusonic, Metron Medical Australia Pty., Ltd., Carrum Downs, Australia) fixed at the bottom. The culture plate was placed on the center of the transducer. The culture plate was covered with the lid to prevent it from being polluted by the surrounding environment. The experiments were performed on a sterile decontamination bench. To prevent the nearby wells from being affected by ultrasound irradiation, cells were planted in only six of 24-well culture plates. During ultrasound irradiation, the plate was agitated slowly, while remaining close to the transducer surface.
Experimental grouping and processes
HeLa cells were conventionally harvested by trypsinization and resuspended in a concentration of 5.0×106 cells/ml in DMEM (300 μl, non-FBS). Firstly, cells were irradiated using various ultrasound parameters and microbubble concentrations. Prior to ultrasound irradiation, LMs were mixed with 0.9% saline at various concentrations (v/v; 3, 6 and 10%). LM suspension (150 μl) and plasmid solution (final concentration 1.0 μg/μl) were fully mixed to prepare the LM/plasmid complexes. Ultrasound parameters were set as: ultrasonic frequency of 1 MHz, pulse repetition frequency of 100 Hz, 20% duty cycle, and ultrasound intensities of 0.8, 1.0 and 1.2 W/cm2 with 3-min exposure.
To investigate the effect of LMs on the transfection and ultrasound exposure time, experiments were divided into the following groups: plasmid DNA group (n=3); plasmid + ultrasound group, 3 wells irradiated for 1 min and 3 wells irradiated for 3 min; LM + plasmid group (n=3); plasmid + LM + ultrasound group (P+ UMLMD), 3 wells irradiated for 1 min and 3 wells irradiated for 3 min. Plasmid solution (150 μl) (10 μg/well) or LM suspension (6%) or LM/plasmid complexes (as described above, LM concentration of 6%) were added to the culture plate. The ultrasound intensity was fixed at 1.0 W/cm2. When all the processes were completed, the culture plates were removed from the tank, wiped dry and returned to the incubator. A total of 8 h following ultrasound irradiation, the medium was replaced by one containing 10% FBS for continuous cultivation.
Cell viability and transgenic expression
Forty-eight hours after ultrasound irradiation, the RFP expression was observed using a fluorescence contrast phase microscope (IX71, Olympus, Japan). The cells were then harvested to assess the cell viability and the transgenic expression using different samples of the same cell suspension.
Propidium iodide (20 μl) (PI, 40 μg/ml, Sigma-Aldrich) was added into the cell suspension. Cells with PI were considered to be dead and cells without PI were considered to be alive. Following a 15 min incubation at room temperature, the cells were stored at 4°C. Using flow cytometry (FACSCalibur, Becton Dickinson, Franklin Lakes, NJ, USA), the ratios of cells stained with or without PI were determined.
Approximately 1×105 cells were obtained from each sample for transgenic expression analysis, using a 550 nm wavelength excitation light and a 585±42 nm wavelength emission light to detect the red fluorescence. The transgenic expression was assessed as the number of cells expressing RFP per total number of survival cells. Data were analyzed using WinMDI software (version 2.8).
In vivo studies
Animal protocol
Animal handling and experimental procedures were approved by the Medical College Animal Experiments Committee. Four-to-six weeks old female Balb/c nu/nu mice, weighing 17–22 g, were maintained in specified pathogen-free (SPF) conditions throughout the experimental period.
Prior to animal modeling, HeLa cells were harvested, collected and centrifuged, and then resuspended in 100 μl DMEM to prepare a single cell suspension. The mice were fixed on a superclean bench according to the principle of aseptic surgery, and inoculated subcutaneously into the flank with 2×106 cells per mouse following local sterilization. The mice were raised under the SPF condition following surgery, and were observed once every two days. Two weeks later, the experiments were initiated when the tumors reached a size of 5–10 mm.
Experimental grouping
A total of 20 mice were randomly divided into 4 experimental groups with 5 mice in each group: Plasmid group, injection of plasmid DNA (50 μg/200 μl) alone; plasmid + ultrasound exposure group; LM + plasmid group, complexes of LM (30 μl, 6%) and plasmid (50 μg) were gently agitated with PBS to a final volume of 200 μl and directly injected; plasmid + LM + ultrasound group (P + UMLMD), complexes of plasmid DNA/LM were injected and followed by local ultrasound irradiation.
The plasmid DNA or LM/plasmid complexes were administered into the tail vein of the mice. The mice were anesthetized by diethylether and fixed on the flats. The tumors were subsequently sonicated using a transducer placed on the skin with a contact gel (Aquasonic 100, Parker Laboratories Inc., WI, USA). Ultrasound parameters were set at 3 MHz, 2 W/cm2, 2 min and 20% duty cycle. During the exposure, the ultrasound transducer was moved in a circular motion to ensure the whole tumor was exposed.
Analysis of transgenic expression in vivo
Three days following ultrasound treatment, the mice were sacrificed by cervical dislocation. The tumor specimens, surrounding tissues, the skin around the tumors, the hearts, livers and muscles, were immediately removed, embedded in optimal cutting temperature compound (OCT, Tissue-Tek, Sakura Finetek, Torrance, CA, USA), and stored at −80°C until further analyses. Cross sections (10 μm) were cut with a cryostat (CM1900, Leica, Germany) and affixed to glass slides. Fluorescence expression and distribution patterns were observed with confocal laser microscopy (Fluoview FV500, Olympus, Japan). The quantitative detection of transfection was performed using flow cytometry.
Histology
The specimens were fixed using formaldehyde, dehydrated with a graded alcohol series, and embedded in paraffin. Hematoxylin and eosin (H&E) staining was performed on the specimens for histopathological evaluation of hemorrhage, necrosis and inflammation.
Statistical analysis
Statistical analyses were performed by the SPSS 13.0 software package (SPSS, Inc., Chicago, IL, USA). All values were expressed as the mean ± SD. Analysis of variance with paired t-test and factorial design analysis of variance (ANOVA) test were used to determine the significance of the difference in a multiple comparison. If the ANOVA was significant, the Tukey’s procedure was used as a post hoc test. P<0.05 was considered to indicate a statistically significant difference.
Results
Effects of UMLMD on the transgenic expression in vitro
As shown in Table I, when the LM concentration was 3 and 10%, there was no significant difference in the transgenic expression among the various ultrasound intensities (F=3.483, P=0.099; F=1.159, P=0.375). When the LM concentration was 6%, RFP expression of 1.0 W/cm2 was higher than that of 0.8 W/cm2 (P=0.017); however, the difference was not significant as compared with 1.2 W/cm2 (P=0.176). When the ultrasound intensity was fixed, the differences of transgenic expression among the various LM concentrations were significant (F=5.715, P=0.041; F=10.238, P=0.012; F=28.631, P=0.001).
Cell injury of different ultrasound intensities and LM concentrations
Ultrasound exposure alone did not damage cells and the cell injury rate was <14%. When the ultrasound intensity was 0.8 or 1.0 W/cm2, the differences among the various LM concentrations were not significant (F=1.072, P=0.414; F=0.376, P=0.773). When the LM concentration was 3 or 6%, there was no apparent cell damage in any experimental group. In addition, the differences between the ultrasound intensities were not significant (F=1.368, P=0.324; F=2.063, P=0.208). The injury ratio was the highest with an ultrasound intensity of 1.2 W/cm2 and 10% LM (F=7.070, P=0.012; F=6.612, P=0.030; Table II).
The factorial design analysis of variance indicated that the main effects analysis of 2 types of parameters were statistically significant (both P<0.01), but there was no existing interaction between them (P>0.05). RFP expression was significantly higher in cells treated with an ultrasound intensity of 1.0 W/cm2 and 6% LM, without causing any apparently adverse effect. According to these results, the subsequent experiments were performed under the optimal UMLMD conditions.
Augmentation of transgenic expression by UMLMD in vitro
Table III shows that without LM, the RFP expression of ultrasound irradiation alone was not significantly higher than that of the plasmid group alone (P=0.816). The transgenic expression exposure of 3 min was not significantly higher than that of 1 min (paired t-test, t=−2.443, P=0.135; Fig. 1A and B). LMs alone were insufficient to transfect the gene into cells without ultrasound irradiation. The differences had no statistical significance as compared with the plasmid alone or the ultrasound irradiation and plasmid group (P=0.095 and P=0.312).
However, the cells that received an injection of plasmid with LM followed by ultrasound irradiation (P + UMLMD) demonstrated a significantly higher transgenic expression than any other group (all P<0.01, Fig. 1C). Moreover, the transgenic expression for an exposure time of 3 min was significantly higher than that of 1 min (paired t-test, t=−5.714, P=0.029; Fig. 1D). These results demonstrated that LM had a markedly enhanced effect on the transgenic expression of UMLMD.
Targeted delivery and enhancement of transgenic expression by UMLMD in vivo
Without ultrasound irradiation, limited RFP expression in the plasmid injection alone group was detected (1.83±1.21%), and the fluorescence signal was weak (Fig. 2A). The plasmid and LM injection group also demonstrated a similar fluorescence expression rate (2.33±1.39%, P=0.753; Fig. 2B). The RFP expression rate of the plasmid injection and ultrasound irradiation group was 3.48±0.18%; however, when compared with the plasmid injection alone, the difference was not significant (P=0.517). In addition, the majority of fluorescent protein expression detected was distributed in the superficial area of the tumors (Fig. 2C). However, when the plasmid was injected with LM followed by ultrasound irradiation, RFP expression increased significantly (23.96±2.13%), with a stronger signal and a greater density (Fig. 2D). As compared with the other three groups, the differences were significant (F=172.954, P<0.001, all P<0.01).
Tissue specificity by UMLMD in vivo
None of the nude mice died during the experiment. Regardless of the ultrasound exposure, a weak RFP expression was evident in certain livers (Fig. 3A), hearts (Fig. 3B) and muscles (Fig. 3C), whereas other organ tissues had no significant expression.
Histological observation
H&E staining revealed that tissue damage was not observed in the tumors (Fig. 4A) and other organs (Fig. 4B-D), which remained intact. Moreover, the results demonstrated no abnormalities, including inflammation or degeneration, in any tissues.
Discussion
For gene therapy, although the viral vector is an effective transgenic method for gene transfection, its safety and side-effects remain a concern for clinical application. In non-viral transgenic technologies, UMLMD is a simple, non-invasive method. It can focus on specific tissues or organs directly and it is beneficial for the localization of the gene of interest. It is safer than other methods, and may be used in clinical applications in the near future. Cell permeability may be transiently changed by sonoporation, in order that macromolecules, including the plasmid DNA are able to enter the cells instantaneously (8,9,21,22). Results of previous studies showed that (8–11,23) the addition of microbubbles were capable of promoting transgenic expression. However, if sonoporation was extremely strong, it would lead to apparent cell death. The ideal concentration of microbubbles should deliver the drug or gene into cells with the greatest efficiency without lethal effect.
A significant problem from the application of the non-viral gene transfer system of UMLMD occurred in our study. This technology provided a new promising approach for gene delivery in vitro and in vivo. However, this technique for the delivery system of shRNA in vitro has yet to be optimized. In the present study, parameters for the delivery system were optimized. Fig. 1 shows that transfection efficiency was affected by the transfection parameters, including ultrasound intensity and exposure time. The optimal conditions were capable of achieving the highest transfection efficiency. Our results demonstrated that the RFP transgenic expression was the highest when LMs were combined with ultrasound exposure, while the cells were not markedly injured. Moreover, the UMLMD was also an effective and tumor-specific transgenic technology in vivo. Plasmid DNA was rapidly transferred to transplanted tumors even under the conditions in the bloodstream and serum, and transgenic expression depended on the ultrasound irradiation site. In this study, the reporter gene was RFP, whose provocation and emission wavelength were longer than other genes such as GFP, and its emission peak was located beyond the scope of the fluorescence background generated by the medium and tissue culture equipment. RFP, which is expressed in mammalian cells effectively, has a high signal-to-noise ratio, is not easy to induce fluorescence quenching, and has a high conversion efficiency. The far-red emissions may be preferred for certain applications due to the lower background autofluorescence in certain tissues (18).
Microbubbles are not only useful as contrast agents, but are also widely used in therapeutic applications. Microbubbles may amplify the cavitation effect of ultrasound, particularly in targeting drug and gene delivery in vitro and in vivo. However, the mean diameter of conventional microbubbles is approximately 2.0–4.5 μm. Tsunoda et al (24) reported that several mice died immediately following i.v. injection due to lethal embolisms in certain organs. It is therefore necessary to develop novel microbubbles and new techniques to improve the transfection efficiency. LMs have been used in clinical ultrasound diagnosis and treatment safely and stably, with low immunogenicity and cytotoxicity. However, LM alone was insufficient to transfect the gene into cells without ultrasound exposure. The transfection efficiency was enhanced by the novel combination of LM and ultrasound exposure via the mechanism of sonoporation. In this study, LMs were composed of polyethyleneglicol (PEG) and liposome, which independently have been used in clinical ultrasound diagnosis and treatment safely and stably with a long intravascular half-life (25). The mean diameter of LMs was smaller than that of red blood cells (26), meaning that it was capable of reaching peripheral tissues and passing through capillary vessels. Therefore, the LMs were used repeatedly to further enhance and maintain the gene expression. Moreover, under ultrasound irradiation, LM significantly promoted transgenic expression. However, when excessive LM was added, the transgenic expression declined and caused cell damage (27). Similarly to another study (28), various ultrasound intensities and irradiation times had a great impact on UMLMD. As the matching of specific ultrasound parameters and transgenic technologies were different, the optimal conditions of various cell types were also different. The ultrasound response differences among various cell lines also lead to different conclusions (29). Furthermore, LM could be developed as a gene transfection tool and delivered into specific tissues or organs. Significantly, the in vivo study concerning the targeted delivery of LMs and the effects of ultrasound allowed for further investigation into the transfection of transplantation tumors in nude mice in our laboratory. For this type of gene transfer system, modulating the biodistribution of the LMs and the plasmid DNA in the systemic injection is crucial. Unlike the in vitro study, ultrasound exposure of 3 MHz facilitated the degree of tumor targeting, indicating the significance of localizing ultrasonic energy in the tumor volume (30). Ultrasound irradiation had no significant impact on other organs. Our results demonstrated that significant transgenic expression and noninvasive, targeting gene transfer were obtained by LM and plasmid DNA complex injections with ultrasound irradiation.
However, there were certain limitations to our study, and further studies are required to investigate the mode of injection and the time point and dose-response correlation in larger animal models. In addition, the optimal conditions in the in vivo experiment, including ultrasound parameters, concentration of LMs and plasmid DNA, are likely to be different from the in vitro experiment. Furthermore, to enhance the tissue specificity of the transgenic expression, several modifications are required and should be studied. For example, certain peptides or receptors on the surface of LMs may be investigated and may specify the gene expression in certain tissues.
In conclusion, in this study, UMLMD was found to enhance the transgenic efficiency without causing any apparent detrimental effect. If the appropriate target gene is added, this transgenic technology is expected to become an effective strategy for human gene therapy, and provide a non-invasive, safe and promising technique for transgenic research.
Acknowledgements
This study was supported by the Medical Research Foundation of Guangdong Province (No. A2010270), the Research Projects of Guangzhou Education Bureau (No. 10A242), the Youth Research Support Projects of the Third Affiliated Hospital of Guangzhou Medical University (No. 2011Y02) and the Medical Research Foundation of Liwan District (No. 20111213067).