A simple method of placing a coronary sinus catheter through the femoral vein in miniature swine

  • Authors:
    • Yupeng Bai
    • Liqun Hu
    • Delong Yu
    • Sheng Peng
    • Mingjing Zhang
    • Xiaogang Liu
    • Ye Gu
  • View Affiliations

  • Published online on: February 22, 2017     https://doi.org/10.3892/etm.2017.4158
  • Pages: 1604-1607
Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

The aim of the present study was to evaluate the feasibility of placing a coronary sinus (CS) catheter through the femoral veins of miniature swine. A total of 16 male domestic pigs (3‑4 months old, 25±2 kg) were used. Firstly, the anatomic structure of the CS ostium of swine heart was observed at different angles under X‑ray. The guide wire and Cobara catheter were subsequently advanced into the right atrium through the femoral vein. Subsequently, the guide wire was retracted behind the fix curve of the Cobara catheter and the catheter bent spontaneously in the absence of supporting guide wire following retraction. The catheter was then gently rotated clockwise to direct the catheter tip to the left allowing the catheter to easily be placed in the CS ostium. This method was associated with a short procedure time: The time on separation of the blood vessels was 15.5±5.8 min and the time of radiation exposure was 112±20 sec. The success rate of placing the catheter to CS ostium was 100%. Only one pig experienced a hematoma after the sheath was pulled out. All swine recovered without serious complications, such as perforation of coronary vein and pericardial tamponade. Therefore, this method of placing CS catheter is simple, safe and reliable, which may offer help for related research.
View Figures
View References

Related Articles

Journal Cover

April-2017
Volume 13 Issue 4

Print ISSN: 1792-0981
Online ISSN:1792-1015

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Bai Y, Hu L, Yu D, Peng S, Zhang M, Liu X and Gu Y: A simple method of placing a coronary sinus catheter through the femoral vein in miniature swine. Exp Ther Med 13: 1604-1607, 2017.
APA
Bai, Y., Hu, L., Yu, D., Peng, S., Zhang, M., Liu, X., & Gu, Y. (2017). A simple method of placing a coronary sinus catheter through the femoral vein in miniature swine. Experimental and Therapeutic Medicine, 13, 1604-1607. https://doi.org/10.3892/etm.2017.4158
MLA
Bai, Y., Hu, L., Yu, D., Peng, S., Zhang, M., Liu, X., Gu, Y."A simple method of placing a coronary sinus catheter through the femoral vein in miniature swine". Experimental and Therapeutic Medicine 13.4 (2017): 1604-1607.
Chicago
Bai, Y., Hu, L., Yu, D., Peng, S., Zhang, M., Liu, X., Gu, Y."A simple method of placing a coronary sinus catheter through the femoral vein in miniature swine". Experimental and Therapeutic Medicine 13, no. 4 (2017): 1604-1607. https://doi.org/10.3892/etm.2017.4158