Open Access

Accuracy of five intraocular lens formulas in eyes with trifocal lens implant

  • Authors:
    • Monica Mălăescu
    • Horia T. Stanca
    • Bogdana Tăbăcaru
    • Adriana Stănilă
    • Simona Stanca
    • Ciprian Danielescu
  • View Affiliations

  • Published online on: June 16, 2020     https://doi.org/10.3892/etm.2020.8891
  • Pages: 2536-2543
  • Copyright: © Mălăescu et al. This is an open access article distributed under the terms of Creative Commons Attribution License.

Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

Accuracy of intraocular lens (IOL) calculation formulas SRK/T, Hoffer Q, Holladay 1, Haigis and Barrett Universal II were compared in prediction of postoperative refraction for multifocal and implants using a single optical biometry device. The authors included 88 refractive lens exchange and cataract surgeries, with AcrySof IQ PanOptix implant (Alcon Laboratories, Inc.). All eyes were divided into three groups based on axial length (AL), group 1: <22 mm (14 eyes), group 2: 22‑24.5 mm (68 eyes) and group 3: >24.5 mm (6 eyes). The refractive prediction error (RPE) and mean absolute error (MAE) were calculated for 5 different formulas: SRK/T, Hoffer Q, Holladay 1, Haigis and Barrett Universal II. For eyes with the AL between 22 mm and 24.5 mm the greatest percentage of eyes with RPEs within ±0.25 D was 32.4% for Haigis formula, followed by Barrett Universal II, Hoffer Q and Holladay 1 with 29.4%. The percentage of eyes with RPEs within ±0.50 D was 100% only for Barrett Universal II and Holladay 1, 94.1% for SRK/T and 91.2% for Haigis and Hoffer Q. The first and third group with AL <22  and >24.5 mm were too small to have statistical significance due to the reluctancy to use multifocal IOLs on extreme ALs. ANOVA test showed no statistical difference (P=0.166) between the RPEs measured for each formula in this cohort. This study showed no statistical difference between formulas for this trifocal lens implant. There was a tendency for the RPE to be within ±0.25 D for most of the eyes with the Haigis formula, and within ±0.50 D for all the eyes with the Barrett Universal II formula in the group with the AL between 22 and 24.5 mm.
View References

Related Articles

Journal Cover

September-2020
Volume 20 Issue 3

Print ISSN: 1792-0981
Online ISSN:1792-1015

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Mălăescu M, Stanca HT, Tăbăcaru B, Stănilă A, Stanca S and Danielescu C: Accuracy of five intraocular lens formulas in eyes with trifocal lens implant. Exp Ther Med 20: 2536-2543, 2020.
APA
Mălăescu, M., Stanca, H.T., Tăbăcaru, B., Stănilă, A., Stanca, S., & Danielescu, C. (2020). Accuracy of five intraocular lens formulas in eyes with trifocal lens implant. Experimental and Therapeutic Medicine, 20, 2536-2543. https://doi.org/10.3892/etm.2020.8891
MLA
Mălăescu, M., Stanca, H. T., Tăbăcaru, B., Stănilă, A., Stanca, S., Danielescu, C."Accuracy of five intraocular lens formulas in eyes with trifocal lens implant". Experimental and Therapeutic Medicine 20.3 (2020): 2536-2543.
Chicago
Mălăescu, M., Stanca, H. T., Tăbăcaru, B., Stănilă, A., Stanca, S., Danielescu, C."Accuracy of five intraocular lens formulas in eyes with trifocal lens implant". Experimental and Therapeutic Medicine 20, no. 3 (2020): 2536-2543. https://doi.org/10.3892/etm.2020.8891